Permit Details

Permit Search

Permit

Roof Replacement or Repair

492 SE PEACOCK TER
LAKE CITY, FL 32025

Permit #
000049045
Application #
63825
Status Completed
  1. Submitted Jan 9, 2024
  2. Issued Jan 18, 2024
  3. Expires Aug 21, 2024
  4. Completed Feb 23, 2024

Property

Parcel #
08715-006
Owner
Kuck Emily Michelle
Acres
0.97
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0405C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Re-Roof
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
24
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
FL17992.R2
Product Manufacturer
Capital Metal Supply,INC.
Product Description
26 GA RIB
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Corrections Needed
  4. Final Review - Payment Needed
  5. Permit Issued

Contractors

  • Lewis G Walker

    Lewis Walker Roofing Inc

    License
    CCC1333551
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Jan 22, 2024

    Passed: Re-Roof - In Progress

    This Project Has A Remodel Permit #49010, Need Engineer To Review. dry In Project And Roof To Protect Structure.

    Inspected by Anthony Aslan

  2. Jan 25, 2024

    Failed: Re-Roof - Final

    Need Architect Or Engineer Report On Gable Truss As Discussed.

    Inspected by Troy Crews

  3. Feb 23, 2024

    Rescheduled 2/23/2024:Re-Roof - Final

    Inspected by Emaleigh Williams

  4. Feb 23, 2024

    Passed: Re-Roof - Final

    Inspected by Troy Crews