Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 672 NE INDIGO DR
LAKE CITY, FL 32055
Parcel #: 04838-117
Acres: 11.64
Owner: Ratliff Robert D, Ratliff Amy B
Subdivision: Osceola Plantations Unr
Zoning: A-3
Flood Zone: A
District: 1
Application #: 62837
Permit #: 000048935
Related Permit:
Submitted: Wednesday, October 4, 2023
Issued: Tuesday, January 2, 2024
Expires: Thursday, November 21, 2024
Completed: Thursday, November 21, 2024
Status: Completed
Septic Release? Yes
Notes:
**THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED A FLOOD ZONE FINISHED FLOOR MUST BE TWO FEET ABOVE DIRT ROAD
Job Details
Elevation regulation Special Flood Hazard Area
Finished floor requirement Two feet above the Dirt road
Fema map number 12023C0215D
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1927
Total Area (Sqft) 3001
Building Height 25.4
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 23-0790
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 300
Review Notes
10/3/2023 Application pending.
10/4/2023 Application submitted by applicant.
10/9/2023 Point Review - On Hold-Incomplete NEEDED * SEALED STRUCTURAL PLANS
10/19/2023 Point Review - Email Sent NEEDED * SEALED STRUCTURAL PLANS
10/19/2023 Point Review - On Hold-Incomplete NEEDED * SEALED STRUCTURAL PLANS
11/9/2023 Point Review - Printed-Online Application
11/21/2023 Plan Review - Corrections Needed need: **manual j & energy forms sqft dosen't match plans.
11/27/2023 Plan Review - On Hold-Incomplete NEED ** MANUAL J & ENERGY FORM SQFT DOSEN'T MATCH PLANS
12/6/2023 Plan Review - On Hold-Incomplete NEED **new MANUAL J & ENERGY FORM SQFT DOSEN'T MATCH PLANS
12/7/2023 Plan Review - Corrections Needed NEED **ENERGY FORM not seer 2 compliant
12/8/2023 Plan Review - Building Approved
12/8/2023 Plan Review - Electrical Approved
12/8/2023 Plan Review - Mechanical Approved
12/8/2023 Plan Review - Plumbing Approved
12/8/2023 Plan Review - Fuel/Gas Approved
12/8/2023 Plan Review - Reviewed
12/18/2023 Zoning Review - Corrections Needed LIDAR INDICATES FINISHED FLOOR WOULD NEED TO BE 4 FOOT ABOVE EXISTING GRADE YOU MAY WANT TO GET ENGINEER LETTER FOR ESTABLISHHING FLOOR HEIGHT
12/19/2023 Zoning Review - Reviewed
12/19/2023 Final Review - Reviewed **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
12/19/2023 Final Review - Contact the Building Dept **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
12/19/2023 Final Review - Reviewed **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
12/19/2023 Final Review - Payment Needed **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
12/29/2023 Final Review - Payment Needed **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
1/2/2024 Permit Issued Permit #000048935 created and approved.
Contractors
Name/ Business License Title Role
Carrie Cason
Stanley Crawford Construction Inc
Liability Insurance & Workers Comp Expired.
CBC1254767 Cert. Building Contractor
Don C Bills Sr
Hometown Plumbing Services Llc
CFC1428890 Plumbing Contractor Subcontractor
Ralph W Laverdure
Rwl Roofing Llc
Liability Insurance Expired.
CCC1328590 Roofing Contractor Subcontractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Stephen M Brisbois
Epic Ac Service (dba) Central Home Heating & Air Llc
Workers Comp Expired.
CAC1819412 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 11/30/2023
Passed: Building - Footer 10 By 20 With Two Number Five Troy Crews 1/18/2024
Passed: Engineering - Setbacks Troy Crews 1/18/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Dvw Only, No Clean Out On Outside At This Time Gary Pitzer 2/6/2024
Passed: Building - Slab Troy Crews 2/8/2024
Passed: Building - Wall Sheathing Gary Pitzer 3/18/2024
Failed: Building - Roof Decking Lots Of Shines ( Nails That Missed Truss Or Rafter) Gary Pitzer 3/18/2024
Failed: Building - Ext Strapping/Wall Sheathing Not Complete Gary Pitzer 3/18/2024
Failed: Building - Strapping Not Complete And Also No Framing Inspection Gary Pitzer 3/18/2024
Passed: Building - Ext Strapping/Wall Sheathing Gary Pitzer 3/21/2024
Passed: Building - Roof Decking Gary Pitzer 3/21/2024
Passed: Building - Strapping Gary Pitzer 3/21/2024
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 4/25/2024
Passed: Mechanical - Rough In Gary Pitzer 4/25/2024
Passed: Electrical - 2nd Rough-In Gary Pitzer 4/25/2024
Passed: Building - Framing Gary Pitzer 4/25/2024
Passed: Building - Insulation Walls Gary Pitzer 5/2/2024
Passed: Electrical - Permanent Power Troy Crews 9/16/2024
Release to power company Troy Crews 9/16/2024
Passed: Building - Final Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. Gary Pitzer 11/18/2024
Certificate-Release Certificate Gary Pitzer 11/21/2024
Documents
File Name Date File Size
Lidar 62837.pdf 2025.07.05 105.37kB
911 Address Form 20231004 081625.pdf 2025.07.05 202.12kB
Manual J Forms 20231208 090755.pdf 2025.07.05 119.08kB
Ratliff Eh 2023-11-30 08.43.41.692.pdf 2025.07.05 700.08kB
Architectural Plans 20231109 082331.pdf 2025.07.04 6.43MB
Original Permit 20240102.pdf 2025.06.22 51.99kB
Termite Certificate_final 20241118 111009.pdf 2025.06.22 106.20kB
Termite Treatment_initial 20240213 110725.pdf 2025.06.22 108.67kB
48935 Water Fucet.pdf 2025.06.22 227.42kB
Reviewed Sealed S.4.pdf 2025.06.21 966.70kB
Reviewed Sealed S.2.pdf 2025.06.21 1.10MB
Reviewed Sealed S.1.pdf 2025.06.21 1.45MB
Reviewed Sealed S.3.pdf 2025.06.21 1.86MB
Win_20240208_09_43_57_pro 2024-02-08 09.44.35.947.jpg 2025.06.20 106.49kB
Win_20240118_10_58_29_pro 2024-01-18 11.01.22.548.jpg 2025.06.20 127.47kB
48935 Measurement.jpg 2025.06.20 315.59kB
48935 Pest Control.jpg 2025.06.20 2.92MB
48935-1 2024-04-30 14.32.06.363.jpg 2025.06.20 1.93MB
48935 2024-04-30 14.32.05.254.jpg 2025.06.20 2.01MB
48935 Blower Door.jpg 2025.06.20 2.49MB
48935 Measurement 2.jpg 2025.06.20 5.35MB
Certificate Of Occupancy 20241121.pdf 2024.11.21 53.83kB
Floodplain Ordinance Notice To Owner 20241119 143415.pdf 2024.11.19 143.60kB
Blower Door Test Results 20241118 133333.pdf 2024.11.18 42.42kB
Power Release-electrical-permanent Power 20240916.pdf 2024.09.16 38.91kB
Subcontractor Form 20231004 114141.pdf 2023.12.23 88.34kB
Reviewed Truss Engineering 62837 2023-12-08 09.42.32.665.pdf 2023.12.23 1,001.00kB
Truss Engineering 20231129 131416.pdf 2023.12.23 911.50kB
Energy Code Forms 20231208 090755.pdf 2023.12.23 56.33kB
Residential Or Commercial Checklist 20231109 115307.pdf 2023.12.23 584.90kB
Recorded Notice Of Commencement 20231004 081626.pdf 2023.12.23 300.35kB
Site Plan 20231005 095041.pdf 2023.12.23 107.27kB
Recorded Deed 20231004 081626.pdf 2023.12.23 74.14kB
Contractor Letter Of Authorization 20231005 092321.pdf 2023.12.23 131.81kB
Product Approval Code Specifications Form 20231004 114141.pdf 2023.12.23 99.74kB
Owner And Contractor Signature Page 20231004 081626.pdf 2023.12.23 137.77kB
Property Appraiser Parcel Details Printed Page 20231004 114141.pdf 2023.12.23 158.14kB