Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 173 SW LANCELOT GLN
LAKE CITY, FL 32024
Parcel #: 03099-216
Acres: 0.57
Owner: Morgan Stephen D, Morgan Lisa P
Subdivision: Stonehenge Phase 2
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 63696
Permit #: 000048904
Related Permit:
Submitted: Thursday, December 21, 2023
Issued: Thursday, December 21, 2023
Expires: Sunday, June 23, 2024
Completed:
Status: Permit Issued
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0380C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 1512
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10124-R27
Product Manufacturer GAF
Product Description Fiberglass reinforced asphalt shingle
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
12/21/2023 City of Lake City Notified of Application within Utility Service Areas LC_WATER,.
12/21/2023 Permit Issued Permit #000048904 created and approved.
Contractors
Name/ Business License Title Role
Fredrick Perry
Fred Perrys Quality Construction
CCC1333355 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Matt Forsyth 12/26/2023
Failed: Re-Roof - Final Request Ridge Vent Opening For Ventilation Matt Forsyth 2/17/2025
Documents
File Name Date File Size