Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 326 SW CHESTERFIELD CIR
LAKE CITY, FL 32024
Parcel #: 03117-128
Acres: 0.49
Owner: Fields Thomas Shelton, Fields Sharon Anne
Subdivision: Crosswinds Phase 1
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 63564
Permit #: 000048874
Related Permit: Culvert: 000048875
Submitted: Friday, December 8, 2023
Issued: Monday, December 18, 2023
Expires: Thursday, May 16, 2024
Completed: Thursday, May 16, 2024
Status: Completed
Septic Release? Yes
Notes:
MFE= 1' ABOVE THE ROAD
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1770
Total Area (Sqft) 2498
Stories 1
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title residential
Setbacks Front 25
Setback Side 1 10
Setback Side 2 10
Setbacks Rear 15
Septic# (00-0000) or (X00-000) 23-0789
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0381D
In floodway N
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
12/8/2023 Point Review - Reviewed
12/12/2023 Plan Review - Plumbing Approved
12/12/2023 Plan Review - Mechanical Approved
12/12/2023 Plan Review - Electrical Approved
12/12/2023 Plan Review - Building Approved
12/12/2023 Plan Review - Reviewed
12/12/2023 Zoning Review - Processing
12/12/2023 Zoning Review - Reviewed
12/14/2023 Final Review - Processing
12/14/2023 Final Review - Processing
12/15/2023 Final Review - Payment Needed
12/18/2023 Permit Issued Permit #000048874 created and approved.
4/15/2024 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Brian T Giebeig
Trent Giebeig Construction,inc.
CRC1330693 Residential Contractor Contractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Derrick L Williams
Dl Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Kenneth R Roche
Ken Roche Plumbing Inc Dba Plumbing Now
CFC1426527 Plumbing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Electrical -1st Underground Rough–In Steel Bond Gary Pitzer 12/19/2023
Failed: Engineering - Final Driveway Needs Culvert Permit. Beach, Garrett 12/19/2023
Passed: Engineering - Setbacks Appear Ok Gary Pitzer 12/19/2023
Passed: Building - Footer 2 #5 Wired Gary Pitzer 12/19/2023
Cancelled: Electrical - Permanent Power Gary Pitzer 12/19/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Dvw Lines, No Gas Nor Water Gary Pitzer 12/29/2023
Passed: Building - Slab Gary Pitzer 1/3/2024
Passed: Electrical - 1st Underground Rough–In Gary Pitzer 1/3/2024
Failed: Engineering - Final Driveway Needs Initial Culvert Permit. Beach, Garrett 1/16/2024
Passed: Electrical - Temporary Service Gary Pitzer 1/24/2024
Release to power company Gary Pitzer 1/24/2024
Passed: Building - Roof Decking Gary Pitzer 2/7/2024
Passed: Building - Wall Sheathing Gary Pitzer 2/7/2024
Passed: Building - Ext Strapping/Wall Sheathing Gary Pitzer 2/9/2024
Passed: Building - Framing Gary Pitzer 2/9/2024
Passed: Building - Strapping Gary Pitzer 2/9/2024
Passed: Building - Framing Gary Pitzer 2/9/2024
Passed: Building - Strapping Windows Screwed And Taped Gary Pitzer 2/9/2024
Passed: Engineering - Initial Driveway Smith, Blake 2/20/2024
Passed: Electrical - 2nd Rough-In Gary Pitzer 2/22/2024
Passed: Mechanical - Rough In Gary Pitzer 2/22/2024
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 2/22/2024
Passed: Building - Insulation Gary Pitzer 2/26/2024
Passed: Electrical - Permanent Power Need Driveway Final Anthony Aslan 4/15/2024
Septic Release Inspection Health Dept 4/19/2024
Release to power company Rec'd Septic & Final Drive Anthony Aslan 4/24/2024
Passed: Engineering - Final Driveway Smith, Blake 4/24/2024
Passed: Building - Final Need Blower Door Anthony Aslan 5/13/2024
Certificate-Release Certificate Rec'd Blower Door Anthony Aslan 5/16/2024
Documents
File Name Date File Size
Big Plans 009.pdf 2024.06.05 13.91MB
Big Plans 008.pdf 2024.06.05 14.04MB
Big Plans 007.pdf 2024.06.05 11.67MB
Big Plans 006.pdf 2024.06.05 13.13MB
Big Plans 005.pdf 2024.06.05 12.47MB
Big Plans 004.pdf 2024.06.05 14.86MB
Big Plans 003.pdf 2024.06.05 14.14MB
Big Plans 002.pdf 2024.06.05 8.21MB
Big Plans 001.pdf 2024.06.05 20.22MB
Blower Door Test Results 20240605 085048.pdf 2024.06.05 547.33kB
Energy Code Forms 20240605 085046.pdf 2024.06.05 3.80MB
Septic Approval Paperwork 20240605 084947.pdf 2024.06.05 559.24kB
Manual J Forms 20240605 084947.pdf 2024.06.05 329.39kB
Recorded Notice Of Commencement 20240605 084946.pdf 2024.06.05 370.95kB
Recorded Deed 20240605 084846.pdf 2024.06.05 659.47kB
911 Address Form 20240605 084847.pdf 2024.06.05 315.02kB
Letter 20240605 084748.pdf 2024.06.05 137.42kB
Property Appraiser Parcel Details Printed Page 20240605 084748.pdf 2024.06.05 391.78kB
Product Approval Code Specifications Form 20240605 084747.pdf 2024.06.05 354.41kB
Residential Or Commercial Checklist 20240605 084746.pdf 2024.06.05 1.98MB
Roof Inspection Affidavit By Contractor 20240605 084653.pdf 2024.06.05 313.75kB
Truss Engineering 20240605 084647.pdf 2024.06.05 22.47MB
Truss Engineering 20240605 084646.pdf 2024.06.05 487.09kB
Owner And Contractor Signature Page 20240605 084447.pdf 2024.06.05 437.93kB
Subcontractor Form 20240605 084447.pdf 2024.06.05 344.55kB
Application Information Page 20240605 084446.pdf 2024.06.05 358.38kB
Certificate Of Occupancy 20240516.pdf 2024.05.16 62.22kB
Blower Door Test 48874 2024-05-16 08.10.14.265.heic 2024.05.16 3.03MB
Power Release-release To Power Company 20240424.pdf 2024.04.24 39.13kB
Power Release-electrical-temporary Service 20240124.pdf 2024.01.24 38.99kB
Recorded Noc.pdf 2024.01.04 83.85kB
48874 2024-01-04 09.34.01.980.jpg 2024.01.04 3.39MB
952 Man 2024-01-04 09.34.01.277.jpg 2024.01.04 2.04MB
48874 2024-01-04 09.33.45.465.jpg 2024.01.04 3.39MB
Noc.jpg 2024.01.04 2.57MB
326 Sw Chesterfield Cir 2023-12-08 11.22.14.579.pdf 2023.12.23 871.57kB
63564 Site Plan 2023-12-12 08.09.50.710.jpg 2023.12.23 2.31MB
Lidar 63564 2023-12-12 12.16.59.948.pdf 2023.12.23 87.84kB
Original Permit 20231218.pdf 2023.12.23 45.89kB