Permit Details

Permit Search

Permit

Roof Replacement or Repair

257 SW EDGEWOOD LN
LAKE CITY, FL 32025

Permit #
000048686
Application #
63399
Status Completed
  1. Submitted Nov 17, 2023
  2. Issued Nov 17, 2023
  3. Expires Sep 18, 2024
  4. Completed Mar 22, 2024

Property

Parcel #
08107-029
Owner
Cohorst Richard P, Cohorst Frances A
Acres
0.50
Subdivision
Edgewood Estates
Zoning
RSF-2
Flood zone
X
District
5

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0292D
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
0.00
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL10124-R25
Product Manufacturer
GAF
Product Description
Shingle
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Mineral Surface

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified
  4. Final Review - Payment Needed
  5. Permit Issued

Contractors

  • Paul R Mcdaniel

    Reed Mcdaniel Construction Inc Dba Reed Roofing

    License
    CCC1330719
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Mar 22, 2024

    Passed: Re-Roof - In Progress

    Per Photos And Affidavit

    Inspected by Gary Pitzer

  2. Mar 22, 2024

    Passed: Re-Roof - Final

    Project Complete, Per Photo And Affidavit

    Inspected by Gary Pitzer