Permit Details

Permit Search

Permit

New Residential Construction

630 SW GERALD CONNER DR
LAKE CITY, FL 32024

Permit #
000048677
Application #
62800
Status Completed
  1. Submitted Sep 28, 2023
  2. Issued Nov 16, 2023
  3. Expires Mar 3, 2026
  4. Completed Sep 4, 2025

Property

Parcel #
03095-112
Owner
Thomas John, Thomas Rebecca
Acres
0.50
Subdivision
Cannon Creek Place Unit 2
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0381D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1740
Total Area (Sqft)
2344
Building Height
19.1
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
23-0601
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Plan Review - Building Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Plumbing Approved
  8. Plan Review - Fuel/Gas Approved
  9. Plan Review - Reviewed
  10. Zoning Review - Corrections Needed
  11. Zoning Review - Corrections Needed
  12. Zoning Review - Corrections Needed
  13. Zoning Review - Reviewed
  14. Final Review - Reviewed
  15. Final Review - Payment Needed
  16. Permit Issued
  17. Final Review - Payment Needed
  18. Final Review - Payment Needed
  19. Final Review - Complete

Contractors

  • Rebecca Thomas

    Jt Builders Llc

    License
    CBC1256094
    Title
    Building Contractor
    Role
    Contractor

    County License & State License & Liability Insurance Expired.

  • Chad White

    Ck Electric Llc

    License
    EC13002222
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Anthony R Franks

    Lane Heating & Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

  • Don C Bills Sr

    Hometown Plumbing Services Llc

    License
    CFC1428890
    Title
    Plumbing Contractor
    Role
    Subcontractor

Inspections

  1. Nov 17, 2023

    Failed: Electrical - Temporary Service

    Need Cover For One Rec. Broken

    Inspected by Matt Forsyth

  2. Nov 21, 2023

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  3. Nov 21, 2023

    Release to power company

    Inspected by Anthony Aslan

  4. Dec 11, 2023

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  5. Dec 13, 2023

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  6. Dec 14, 2023

    Failed: Building - Monolithic Slab

    Need Compaction Test

    Inspected by Anthony Aslan

  7. Dec 18, 2023

    Passed: Building - Monolithic Slab

    Inspected by Anthony Aslan

  8. Dec 18, 2023

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  9. Jan 9, 2024

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  10. Jan 9, 2024

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  11. Jan 25, 2024

    Passed: Building - Framing

    Inspected by Anthony Aslan

  12. Jan 25, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  13. Jan 25, 2024

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  14. Jan 25, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  15. Feb 5, 2024

    Passed: Building - Insulation

    Walls And Ceiling

    Inspected by Anthony Aslan

  16. Apr 9, 2024

    Passed: Electrical - Permanent Power

    Need Septic Final need Driveway Final-- Assessments Paid Prior To Final Being Granted

    Inspected by Anthony Aslan

  17. Jul 11, 2024

    Septic Release Inspection

    Inspected by Health Dept

  18. Jul 26, 2024

    Release to power company

    Inspected by Anthony Aslan

  19. Sep 4, 2025

    Passed: Building - Final

    Need Co's Paid

    Inspected by Anthony Aslan

Documents