Permit Details

Permit Search

Permit

Roof Replacement or Repair

244 SE HORIZON GLN
LAKE CITY, FL 32025

Permit #
000048531
Application #
63184
Status Completed
  1. Submitted Oct 30, 2023
  2. Issued Oct 30, 2023
  3. Expires May 13, 2024
  4. Completed Nov 15, 2023

Property

Parcel #
08679-006
Owner
Hudson Blaine Keith
Acres
10.31
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0313D
Type Roofing Job
Overlay with Metal
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
REPLACE WOOD AS NEEDED
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
43
No. of Stories
1
Roof Pitch
4:12 or Greater
Type of New Roofing Product
Metal
Florida Product Approval Number
FL17992.1R2
Product Manufacturer
Capital
Product Description
26 GA Rib
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
Other (explain)
Sealed roof decking explanation for other option.
Metal Roof-Over. No underlayment needed.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Second Roof Pitch (if applicable)
4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified
  4. Final Review - Payment Needed
  5. Permit Issued

Contractors

  • Lewis G Walker

    Lewis Walker Roofing Inc

    License
    CCC1333551
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Nov 3, 2023

    Failed: Re-Roof - In Progress

    No Work In Progress

    Inspected by Anthony Aslan

  2. Nov 9, 2023

    Passed: Re-Roof - In Progress

    In Progress With Wood Furring Over Existing Shingle Roof

    Inspected by Gary Pitzer

  3. Nov 15, 2023

    Passed: Re-Roof - Final

    Metal Roof Over Existing Shingle On Furring Strips, Has Off Ridge Vent Openings Under Metal And Also Gable Vents, New Boots

    Inspected by Gary Pitzer