Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 684 SW WHITETAIL CIR
LAKE CITY, FL 32024
Parcel #: 02732-543
Acres: 0.33
Owner: Clemons Daniel E, Clemons Malinda T
Subdivision: Deer Creek Phase 2
Zoning: RSF/MH-3
Flood Zone: X
District: 3
Application #: 62347
Permit #: 000048004
Related Permit:
Submitted: Friday, August 25, 2023
Issued: Monday, August 28, 2023
Expires: Monday, September 11, 2023
Completed: Monday, September 11, 2023
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Partial Roof Repairs
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 21
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Roof
Type of New Roofing Product Other
Florida Product Approval Number n/a
Product Manufacturer n/a
Product Description n/a
Other Roofing Product Type Not Listed Remove all existing screws and replace with #14 lifetime screws. The overlap seams do not have Butyl Tape, install butyl tape on all seams.
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0290D
Review Notes
8/23/2023 Application pending.
8/25/2023 Application submitted by applicant.
8/25/2023 City of Lake City Utilities Notified City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
8/25/2023 Final Review - Payment Needed
8/28/2023 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - Final Matt Forsyth 9/11/2023