Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 302 SW CROW TER
FORT WHITE, FL 32038
Parcel #: 09925-108
Acres: 10.01
Owner: Price Mose W Jr, Price Danyel
Subdivision: Old Niblack Farm Unr
Zoning: A-3
Flood Zone: X
District: 2
Application #: 62004
Permit #: 000047976
Related Permit: Culvert Waiver: 000047974
Submitted: Tuesday, July 25, 2023
Issued: Thursday, August 24, 2023
Expires: Wednesday, July 24, 2024
Completed: Wednesday, July 24, 2024
Status: Completed
Septic Release? Yes
Notes:
MFE= 1' ABOVE THE ROAD
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0495C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 2
Heated Area (Sqft) 1685
Total Area (Sqft) 2983
Building Height 27
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 23-0579
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
7/25/2023 Application pending.
7/25/2023 Application submitted by applicant.
7/27/2023 Point Review - Printed-Online Application NEEDED: *BLAKE CONSTRUCTION UPDATED LIABILITY *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
7/27/2023 Point Review - Reviewed NEEDED: *BLAKE CONSTRUCTION UPDATED LIABILITY *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/3/2023 Plan Review - Building Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/3/2023 Plan Review - Electrical Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/3/2023 Plan Review - Mechanical Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/3/2023 Plan Review - Plumbing Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/3/2023 Plan Review - Fuel/Gas Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/3/2023 Plan Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/9/2023 Zoning Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/17/2023 Final Review - Reviewed ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/17/2023 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/24/2023 Permit Issued Permit #000047976 created and approved.
Contractors
Name/ Business License Title Role
Blake Lunde Ii
Blake Construction Company Of North Florida Inc
Liability Insurance Expired.
CBC1253408 Building Contractor Contractor
Don C Bills Sr
Hometown Plumbing Services Llc
CFC1428890 Plumbing Contractor Subcontractor
Blake N Lunde Ii
Blake Roofing Inc
Liability Insurance Expired.
CCC1331699 Cert. Roofing Subcontractor
Matthew H Burns
Burns Electrical Services Inc
EC13006531 Electrical Contractor Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Anthony Aslan 9/7/2023
Release to power company Anthony Aslan 9/7/2023
Passed: Engineering - Setbacks Anthony Aslan 9/18/2023
Passed: Building - Footer Anthony Aslan 9/18/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 10/13/2023
Passed: Building - Slab Anthony Aslan 10/17/2023
Passed: Building - Roof Decking Anthony Aslan 11/16/2023
Passed: Building - Wall Sheathing Nails Missing Red Marker Anthony Aslan 11/16/2023
Passed: Building - Framing Anthony Aslan 12/15/2023
Passed: Building - Strapping Anthony Aslan 12/15/2023
Passed: Electrical - 2nd Rough-In Check Smokes At Insulation Downstairs Bedrooms Anthony Aslan 12/15/2023
Passed: Mechanical - Rough In Anthony Aslan 12/15/2023
Passed: Plumbing/Gas - 2nd Rough-In Check Nail Guards At Insulation Anthony Aslan 12/15/2023
Failed: Building - Insulation Need Letter From Insulator, Sheet Rock Being Installed Unable To See Multiple Places Anthony Aslan 1/17/2024
Passed: Building - Insulation Rec'vd Letter Anthony Aslan 1/18/2024
Passed: Electrical - Permanent Power Need Septic Release Anthony Aslan 4/25/2024
Release to power company Rec'd Septic Anthony Aslan 5/21/2024
Septic Release Inspection Health Dept 5/21/2024
Passed: Building - Final Need Blower Door-- Rec'd Anthony Aslan 7/16/2024
Certificate-Release Certificate Anthony Aslan 7/24/2024
Documents
File Name Date File Size
Power Release-electrical-temporary Service 20230907.pdf 2025.07.05 11.47kB
Energy Code Forms 20230725 114431.pdf 2025.07.05 85.51kB
Product Approval Code Specifications Form 20230725 125516.pdf 2025.07.05 135.13kB
Subcontractor Form 20230725 130959.pdf 2025.07.05 124.17kB
Lidar 62004 2023-08-09 12.57.24.128.pdf 2025.07.05 183.02kB
911 Address Form 20230725 132222.pdf 2025.07.05 217.37kB
Site Plan 20230725 114432.pdf 2025.07.05 178.61kB
Manual J Forms 20230725 114431.pdf 2025.07.05 84.90kB
Truss Engineering 20230725 114610.pdf 2025.07.05 350.01kB
Residential Or Commercial Checklist 20230725 125516.pdf 2025.07.04 760.74kB
Property Appraiser Parcel Details Printed Page 20230725 114432.pdf 2025.07.04 745.54kB
Reviwed Architectural Plans 62004 2023-08-03 09.18.54.72.pdf 2025.07.04 2.62MB
Architectural Plans 20230725 114430.pdf 2025.07.04 2.61MB
Reviewed Structural Engineering 62004 2023-08-03 09.18.54.869.pdf 2025.07.04 4.25MB
Structural Engineering And Wind Load Calculations 20230725 114432.pdf 2025.07.04 4.22MB
Blower Door Test Results 20240723 074833.pdf 2025.06.22 97.11kB
Letter 20240118 094047.pdf 2025.06.22 79.63kB
Termite Certificate_final 20240717 081147.pdf 2025.06.22 143.60kB
Intial Termite 47976 2023-10-18 08.13.18.116.jpg 2025.06.20 100.09kB
Certificate Of Occupancy 20240724.pdf 2024.07.24 62.22kB
Blower Door Test Results 20240717 072344.pdf 2024.07.17 83.51kB
Power Release-release To Power Company 20240521.pdf 2024.05.21 39.18kB
Recorded Notice Of Commencement 20230905 105136.pdf 2023.12.22 102.61kB
Truss Engineering 20230725 114434.pdf 2023.12.22 486.27kB
Owner And Contractor Signature Page 20230725 112146.pdf 2023.12.22 79.96kB
Recorded Deed 20230725 111327.pdf 2023.12.22 266.89kB
Reviewed Truss Engineering 62004 2023-08-03 09.18.55.994.pdf 2023.12.22 535.23kB
Septic Approval Paperwork 20230814 121346.pdf 2023.12.22 1.03MB
Original Permit 20230824.pdf 2023.08.24 46.08kB