Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 6067 SE COUNTY ROAD 252
LAKE CITY, FL 32025
Parcel #: 10513-024
Acres: 19.99
Owner: Garling Jeremiah, Robinson Cassie
Subdivision: High Falls Unr
Zoning: A-3
Flood Zone: A
District: 4
Application #: 61863
Permit #: 000047933
Related Permit:
Submitted: Wednesday, July 12, 2023
Issued: Monday, August 21, 2023
Expires: Thursday, January 23, 2025
Completed: Thursday, January 23, 2025
Status: Completed
Septic Release? Yes
Notes:

Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0410C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1802
Total Area (Sqft) 2226
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 23-0431
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
7/12/2023 Point Review - On Hold-Incomplete NEEDED * OWNERS SIGNATURE ON OWNER AND CONTRACTOR SIGNATURE PAGE * CONTRACTORS SIGNATURE PAGE IS MISSING NOTARY STAMP ON CONTRACTOR'S SIGNATURE * UPDATED STATE LICENSE AND LIABILITY FOR GARY NEWSOME * SITE PLAN SHOWING DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME * TRUSS ENGINEERING * ENERGY CALCS * MANUAL J * SIGNED SUB FORM FOR ALL TRADES ( MECHANICAL, ELECTRICAL, ROOFING) * DIGITAL COPIES OF ENGINEERING TO BE EMAILED OR UPLOADED (CAN NOT PRINT DIGITAL SEALED DOCUMENTS) * RESIDENTAL CHECKLIST
7/28/2023 Point Review - Processing NEEDED * SITE PLAN SHOWING DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME * SIGNED SUB FORM FOR ALL TRADES (ELECTRICAL, ROOFING) * DIGITAL COPIES OF ENGINEERING TO BE EMAILED OR UPLOADED (CAN NOT PRINT DIGITAL SEALED DOCUMENTS) * UPDATED STATE LICENSE, LIABILITY, WORKERS COMP & EXEMPTION FOR ARTHUR (PAUL) P KING JR
7/28/2023 Plan Review - Documents Required NEEDED * SITE PLAN SHOWING DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME * SIGNED SUB FORM FOR ALL TRADES (ELECTRICAL, ROOFING) * DIGITAL COPIES OF ENGINEERING TO BE EMAILED OR UPLOADED (CAN NOT PRINT DIGITAL SEALED DOCUMENTS) * UPDATED STATE LICENSE, LIABILITY, WORKERS COMP & EXEMPTION FOR ARTHUR (PAUL) P KING JR
8/3/2023 Plan Review - Plumbing Approved NEEDED: * UPDATED STATE LICENSE FOR ARTHUR (PAUL) P KING JR *ENV HEALTH SIGNED SITE PLAN APPROVAL *NEWSOME REGISTERED PLUMBING LICENSE NEEDS TO BE UPDATED
8/3/2023 Plan Review - Mechanical Approved NEEDED: * UPDATED STATE LICENSE FOR ARTHUR (PAUL) P KING JR *ENV HEALTH SIGNED SITE PLAN APPROVAL *NEWSOME REGISTERED PLUMBING LICENSE NEEDS TO BE UPDATED
8/3/2023 Plan Review - Electrical Approved NEEDED: * UPDATED STATE LICENSE FOR ARTHUR (PAUL) P KING JR *ENV HEALTH SIGNED SITE PLAN APPROVAL *NEWSOME REGISTERED PLUMBING LICENSE NEEDS TO BE UPDATED
8/3/2023 Plan Review - Building Approved NEEDED: * UPDATED STATE LICENSE FOR ARTHUR (PAUL) P KING JR *ENV HEALTH SIGNED SITE PLAN APPROVAL *NEWSOME REGISTERED PLUMBING LICENSE NEEDS TO BE UPDATED
8/3/2023 Plan Review - Reviewed NEEDED: * UPDATED STATE LICENSE FOR ARTHUR (PAUL) P KING JR *ENV HEALTH SIGNED SITE PLAN APPROVAL *NEWSOME REGISTERED PLUMBING LICENSE NEEDS TO BE UPDATED
8/3/2023 Zoning Review - Documents Required NEEDED: * UPDATED STATE LICENSE FOR ARTHUR (PAUL) P KING JR *ENV HEALTH SIGNED SITE PLAN APPROVAL *NEWSOME REGISTERED PLUMBING LICENSE NEEDS TO BE UPDATED
8/7/2023 Zoning Review - Reviewed NEEDED: *NEWSOME TO COMPLETE RENEWAL FOR REGISTERED PLUMBING LICENSE-- CONTACT 386-758-1008, ASK FOR EMALEIGH OR MELISSA
8/7/2023 Final Review - Processing NEEDED: *NEWSOME TO COMPLETE RENEWAL FOR REGISTERED PLUMBING LICENSE-- CONTACT 386-758-1008, ASK FOR EMALEIGH OR MELISSA
8/10/2023 Final Review - Contact the Building Dept *NEWSOME TO COMPLETE RENEWAL FOR REGISTERED PLUMBING LICENSE-- CONTACT 386-758-1008
8/18/2023 Final Review - Reviewed
8/18/2023 Final Review - Payment Needed
8/21/2023 Permit Issued Permit #000047933 created and approved.
5/20/2024 Final Review - Payment Needed
6/7/2024 Final Review - Documents Required TERMITE FINAL NEEDED TO CLOSE PERMIT
12/18/2024 Final Review - Documents Required TERMITE FINAL NEEDED TO CLOSE PERMIT
1/14/2025 Final Review - Documents Required TERMITE FINAL NEEDED TO CLOSE PERMIT
Contractors
Name/ Business License Title Role
Gary Newsome
G - N Construction Company Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CBC1250895 Cert. Build.contractor Contractor
Arthur (paul) P King Jr
Pauls Heating & Air Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CAC1813957 Cert Class B A/c Subcontractor
Gary D Newsome
G - N Construction Company Inc
Liability Insurance & Workers Comp Expired.
RF0060370 Reg. Plumbing Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 7/14/2023
Passed: Building - Footer Troy Crews 8/23/2023
Passed: Engineering - Setbacks Troy Crews 8/23/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 8/23/2023
Passed: Building - Slab Anthony Aslan 8/24/2023
Cancelled: Building - Roof Decking Anthony Aslan 9/29/2023
Cancelled: Building - Wall Sheathing Anthony Aslan 9/29/2023
Passed: Building - Roof Decking Anthony Aslan 10/2/2023
Passed: Building - Wall Sheathing Anthony Aslan 10/2/2023
Passed: Building - Framing Anthony Aslan 10/30/2023
Passed: Electrical - 2nd Rough-In Anthony Aslan 10/30/2023
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 10/30/2023
Failed: Mechanical - Rough In No Straps On Exhaust Venting, Duct Tape Is Not Allowed And Duct At That Location Is Not Allowed no Gaskets On Supply And Return Drops Anthony Aslan 10/30/2023
Passed: Mechanical - Rough In Anthony Aslan 11/3/2023
Passed: Building - Insulation Anthony Aslan 11/3/2023
Passed: Electrical - Permanent Power Troy Crews 5/8/2024
Release to power company Troy Crews 5/8/2024
Failed: Building - Final No Gas Connected electrical Wires In Outside Panel c/o's Paid uv Insulation On A/c Lines Anthony Aslan 5/20/2024
Passed: Building - Final Need Termite Final Anthony Aslan 5/28/2024
Certificate-Release Certificate Final Termite Recieved Troy Crews 1/23/2025
Documents
File Name Date File Size
Roof Layout 2023-07-20 09.46.52.705.pdf 2025.07.05 207.05kB
Roof Inspection Affidavit By Contractor 20230822 102546.pdf 2025.07.05 188.62kB
Subcontractor Form 20230726 125948.pdf 2025.07.05 199.02kB
Subcontractor Form 20230822 102347.pdf 2025.07.05 203.37kB
Application Information Page 20230822 102346.pdf 2025.07.05 225.38kB
Product Approval Code Specifications Form 20230822 102448.pdf 2025.07.05 235.03kB
Septic Approval Paperwork 20230822 102648.pdf 2025.07.05 217.59kB
Septic Approval Paperwork 20230822 102547.pdf 2025.07.05 217.51kB
Owner And Contractor Signature Page 20230822 102446.pdf 2025.07.05 378.30kB
Truss 2023-07-20 09.46.53.298.pdf 2025.07.05 253.05kB
Recorded Deed 20230822 102648.pdf 2025.07.05 301.00kB
Approved Truss Plans 61863 2023-08-03 15.42.06.662.pdf 2025.07.05 289.46kB
Approved Truss Plans 61863 2023-07-28 07.29.13.515.pdf 2025.07.05 289.45kB
Marriage Certificate 2023-07-21 14.52.21.948.pdf 2025.07.05 174.76kB
Noc 2023-08-23 09.40.48.356.pdf 2025.07.05 243.19kB
6067 Se County Road 252 2023-07-12 09.37.34.222.pdf 2025.07.04 217.38kB
Deed 2023-07-13 13.46.13.228.pdf 2025.07.04 426.24kB
Residential Or Commercial Checklist 20230822 102447.pdf 2025.07.04 1.44MB
Structural Analysis Report 20230822 102646.pdf 2025.07.04 1.56MB
Termite Final 252 2025-01-23 14.15.30.463.jpg 2025.07.03 1.10MB
Certificate Of Occupancy 20250123.pdf 2025.06.23 53.19kB
Blower Door Test Results 20240520 013847.pdf 2025.06.22 220.40kB
Energy Calcs And Manual J.pdf 2025.06.22 221.91kB
Power Release-electrical-permanent Power 20240508.pdf 2024.05.08 38.88kB
Garling Ev 2023-08-04 10.41.07.449.pdf 2023.12.22 518.74kB
Fire Report 2023-07-13 14.09.43.423.pdf 2023.12.22 115.33kB
Se_johnnorrisconst_newsome_06012023 Signed.pdf 2023.12.22 1.12MB
Approved Structural 61863 2023-08-03 15.44.58.956.pdf 2023.12.22 1.12MB
Truss Engineering 2023-07-20 09.46.52.955.pdf 2023.12.22 789.73kB
Floor Plan 2023-07-13 13.46.49.930.pdf 2023.12.22 284.01kB
Original Permit 20230821.pdf 2023.08.21 44.07kB
Site Plan.pdf 2023.08.03 297.00kB