Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 275 SW THISTLEWOOD LN
FORT WHITE, FL 32038
Parcel #: 04056-118
Acres: 1.20
Owner: Terry Craig, Terry Lisa
Subdivision: Thornwood
Zoning:
Flood Zone: X
District: 2
Application #: 58795
Permit #: 000047842
Related Permit: Culvert: 000047843
Submitted: Wednesday, June 14, 2023
Issued: Monday, August 7, 2023
Expires: Thursday, December 7, 2023
Completed: Thursday, December 7, 2023
Status: Completed
Septic Release? Yes
Notes:

Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1843
Total Area (Sqft) 2716
Stories 1
Building Height 9
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 23-0087
Service Amps 200
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Fema map number 12023C0490C
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
1/23/2023 Application pending.
6/27/2023 Application submitted by applicant.
6/29/2023 Point Review - Printed-Online Application NEEDED * UPDATED EMPLOYEES WORKERS COMP FOR RYAN C BEVILLE * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Plan Review - Corrections Needed NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Plan Review - Building Approved NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Plan Review - Electrical Approved NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Plan Review - Mechanical Approved NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Plan Review - Plumbing Approved NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Plan Review - Fuel/Gas Approved NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Plan Review - Reviewed NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Zoning Review - Documents Required NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS * SITE PLAN WITH DISTANCES FROM ALL 4 PROPERTY LINES TO PROPOSED HOME
7/10/2023 Zoning Review - Documents Required NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS
7/11/2023 Zoning Review - Documents Required NEEDED **ENERGY FORM & MANUAL J NEED TO COMPLY WITH SEER2 (NEED BY FINAL REVIEW) * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS
7/14/2023 Zoning Review - Reviewed * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS
7/14/2023 Final Review - Processing * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS
7/26/2023 Final Review - Documents Required * UPDATED WORKERS COMP FOR SAMUEL L ROBERTS
8/7/2023 Final Review - Reviewed
8/7/2023 Final Review - Payment Needed
8/7/2023 Permit Issued Permit #000047842 created and approved.
11/7/2023 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Jeffrey P Bokor
Dwc Contracting Llc
CGC1517145 General Contractor Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Samuel L Roberts
Air Ducks Inc
CAC1817288 Class "b" A/c Subcontractor
James Butler Jr
Butler Plumbing Of Gainesville Inc
CFC057960 Plumbing Contractor Subcontractor
Jeffrey Bokor
Dwc Contracting Llc
CCC1329756 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 8/9/2023
Passed: Electrical - Temporary Service Anthony Aslan 8/9/2023
Release to power company Anthony Aslan 8/9/2023
Passed: Engineering - Initial Driveway Smith, Blake 8/10/2023
Passed: Building - Monolithic Slab Anthony Aslan 8/17/2023
Passed: Engineering - Setbacks Anthony Aslan 8/17/2023
Rescheduled 9/11/2023:Building - Roof Decking Matt Forsyth 9/8/2023
Rescheduled 9/11/2023:Building - Wall Sheathing Matt Forsyth 9/8/2023
Passed: Building - Wall Sheathing Checking Left Front In Morning (checked)aa Anthony Aslan 9/11/2023
Passed: Building - Roof Decking Anthony Aslan 9/11/2023
Failed: Electrical - 2nd Rough-In No Framing Inspection, Post Missing Strapping, Anchors Missing, Stud Packs Under Charter Girder Truss Anthony Aslan 9/22/2023
Failed: Mechanical - Rough In No Framing Inspection straps Missing On Exhaust Ducts nail Guard On Dryer Missing Anthony Aslan 9/22/2023
Failed: Plumbing/Gas - 2nd Rough-In No Framing Inspection Anthony Aslan 9/22/2023
Passed: Electrical - 2nd Rough-In Anthony Aslan 9/26/2023
Failed: Mechanical - Rough In Exhaust Fan Ducts No Strapping Anthony Aslan 9/26/2023
Failed: Plumbing/Gas - 2nd Rough-In No Pressure, Looks Like Framer Brokebpipe Drilling Anchor Anthony Aslan 9/26/2023
Passed: Building - Framing Corrections Made Anthony Aslan 9/26/2023
Passed: Mechanical - Rough In Anthony Aslan 10/2/2023
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 10/2/2023
Passed: Building - Insulation Walls Only Anthony Aslan 10/2/2023
Cancelled: Mechanical - Rough In Anthony Aslan 11/8/2023
Septic Release Inspection Health Dept 11/8/2023
Passed: Electrical - Permanent Power Need Driveway Final Anthony Aslan 11/8/2023
Passed: Engineering - Final Driveway Beach, Garrett 11/13/2023
Release to power company Rec'd Septic & Drive Anthony Aslan 11/21/2023
Passed: Building - Final Need Final Termite picture Of Kitchen Vent And Anchors On Condenser Anthony Aslan 12/6/2023
Certificate-Release Certificate Anthony Aslan 12/7/2023
Documents
File Name Date File Size
Original Permit 20230807.pdf 2023.12.23 45.81kB
Subcontractor Form 20230125 141126.pdf 2023.12.23 815.67kB
Termite Certificate_final 20231206 161741.pdf 2023.12.23 188.18kB
Septic Approval Paperwork 20230222 160714.pdf 2023.12.23 976.17kB
Compaction Test.pdf 2023.12.23 362.10kB
Property Appraiser Parcel Details Printed Page 20230124 161453.pdf 2023.12.23 645.16kB
Recorded Notice Of Commencement 20230713 114926.pdf 2023.12.23 743.11kB
Power Release-release To Power Company 20231121.pdf 2023.12.23 39.15kB
Power Release-electrical-temporary Service 20230809.pdf 2023.12.23 39.02kB
Termite Treatment_initial 20231116 145334.pdf 2023.12.23 138.64kB
Town Of Fort White Compliance Letter.pdf 2023.12.23 139.93kB
Architectural Plans 20230124 160336.pdf 2023.12.23 3.25MB
Reviewed Architectural Plans 58795 2023-07-10 09.16.14.122.pdf 2023.12.23 3.28MB
Energy Code Forms 20230612 122445.pdf 2023.12.23 476.49kB
Termite Certificate_final 20230818 081347.pdf 2023.12.23 182.10kB
Reviewed Structural Engineering And Wind Load Calculations 58795 2023-07-10 09.16.13.731.pdf 2023.12.23 693.97kB
Manual J Forms 20230126 145928.pdf 2023.12.23 182.84kB
Truss Engineering 20230124 155930.pdf 2023.12.23 1.98MB
Bdt 47842 2023-12-06 11.36.16.639.heic 2023.12.23 3.82MB
Owner And Contractor Signature Page 20230124 155930.pdf 2023.12.23 1.35MB
Residential Or Commercial Checklist 20230612 133024.pdf 2023.12.23 5.45MB
Manual J Forms 20230726 154324.pdf 2023.12.23 203.05kB
Product Approval Code Specifications Form 20230612 122729.pdf 2023.12.23 933.15kB
Structural Engineering And Wind Load Calculations 20230126 145928.pdf 2023.12.23 693.97kB
911 Address Form 20230124 155929.pdf 2023.12.23 283.63kB
Recorded Deed 20230123 145009.pdf 2023.12.23 81.36kB
Certificate Of Occupancy 20231207.pdf 2023.12.23 62.18kB