Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 264 SW RANDALL TER
LAKE CITY, FL 32024
Parcel #: 03153-032
Acres: 0.68
Owner: Bryant Jerry Wallace, Bryant Lori Ann
Subdivision: Piccadilly Park Replat Unr
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 61789
Permit #: 000047618
Related Permit:
Submitted: Thursday, July 6, 2023
Issued: Friday, July 7, 2023
Expires: Monday, July 17, 2023
Completed: Monday, July 17, 2023
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0381D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Remove existing shingles and replace with new shingles.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 3395
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number 18355.1
Other Roofing Product Type Not Listed 2 ply modified bitumen on slopes lower than 2/12.
Product Manufacturer TAMKO Building Products LLC
Product Description ASTM D3462 asphalt shingles and hip and ridge shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.;two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: Use Existing
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
7/6/2023 Application pending.
7/6/2023 Application submitted by applicant.
7/6/2023 Final Review - Corrections Needed SELECT ONLY ONE ROOF UNDERLAYMENT OPTION
7/7/2023 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Donald Burnsed
True Force Roofing
CCC1333814 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress In Progress With Shingle Removal And Underlayment Gary Pitzer 7/11/2023
Passed: Re-Roof - Final Lack Dem. Shingle Roof Covering, Vented Ridge, New Trim Gary Pitzer 7/17/2023