Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 359 SW HEATHRIDGE DR
LAKE CITY, FL 32024
Parcel #: 02438-106
Acres: 0.50
Owner: Twentyeight Fourteen Llc,
Subdivision: Emerald Cove Phase 1
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 61473
Permit #: 000047506
Related Permit: Culvert Waiver: 000047507
Submitted: Wednesday, June 7, 2023
Issued: Tuesday, June 20, 2023
Expires: Tuesday, March 19, 2024
Completed: Tuesday, March 19, 2024
Status: Completed
Septic Release? Yes
Notes:
ELEVATION CONFIRMATION REC'D @ 104.67'
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 103'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0280D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 20'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 20' (easement)
Stories 1
Heated Area (Sqft) 1702
Total Area (Sqft) 2433
Building Height 18
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 23-0372
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
6/7/2023 Point Review - Received-Hard Copy Application
6/7/2023 Point Review - Reviewed
6/12/2023 Plan Review - Corrections Needed
6/15/2023 Plan Review - Building Approved
6/15/2023 Plan Review - Electrical Approved
6/15/2023 Plan Review - Mechanical Approved
6/15/2023 Plan Review - Plumbing Approved
6/15/2023 Plan Review - Fuel/Gas Approved
6/15/2023 Plan Review - Reviewed
6/16/2023 Zoning Review - Reviewed
6/16/2023 Final Review - Processing
6/16/2023 Final Review - Reviewed
6/16/2023 Final Review - Payment Needed
6/20/2023 Permit Issued
1/29/2024 Final Review - Payment Needed
1/30/2024 Final Review - Payment Needed
2/23/2024 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Anthony George,jr.
George Construction Llc
Workers Comp Expired.
CGC016583 General Contractor Contractor
Charles R Sanford
Energy Electric Inc
Workers Comp Expired.
EC0000175 Cert. Electrical Subcontractor
Harry D Moseley Sr
Harrys Heating & Air Conditioning Inc
County License & State License Expired.
RA0030316 Class A A/c Contractor Subcontractor
Roger Whiddon
Lake City Plumbing Inc
CFC1428686 Cert Plumbing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Matt Forsyth 7/12/2023
Passed: Engineering - Setbacks Matt Forsyth 7/12/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 8/23/2023
Passed: Building - Slab Matt Forsyth 9/6/2023
Passed: Building - Wall Sheathing Matt Forsyth 10/18/2023
Passed: Building - Framing Troy Crews 11/21/2023
Passed: Electrical - 2nd Rough-In Troy Crews 11/21/2023
Passed: Mechanical - Rough In Troy Crews 11/21/2023
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 11/21/2023
Passed: Building - Insulation Matt Forsyth 11/28/2023
Septic Release Inspection Health Dept 1/24/2024
Cancelled: Electrical - Permanent Power Melissa Garber 1/30/2024
Passed: Electrical - Permanent Power Troy Crews 1/30/2024
Release to power company Troy Crews 1/30/2024
Passed: Electrical - Permanent Power Troy Crews 1/30/2024
Release to power company Troy Crews 1/30/2024
Release to power company Meter Socket Changed Troy Crews 2/5/2024
Passed: Electrical - Permanent Power Meter Combo Changed Again Troy Crews 2/9/2024
Release to power company Troy Crews 2/9/2024
Passed: Building - Final Matt Forsyth 3/19/2024