Permit Details

Permit Search

Permit

New Residential Construction

1507 SW MIXSON RD
LAKE CITY, FL 32024

Permit #
000047448
Application #
61045
Status Completed
  1. Submitted May 3, 2023
  2. Issued Jun 13, 2023
  3. Expires May 29, 2024
  4. Completed Dec 1, 2023

Property

Parcel #
09272-006
Owner
Krygier Stephen V, Krygier Gayle A
Acres
22.21
Subdivision
Mixon Road Unr
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0395C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Stories
1
Heated Area (Sqft)
1911
Total Area (Sqft)
3143
Building Height
19
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
23-0314
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Point Review - Reviewed
  5. Plan Review - Building Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Plumbing Approved
  9. Plan Review - Fuel/Gas Approved
  10. Plan Review - Reviewed
  11. Zoning Review - Corrections Needed
  12. Zoning Review - Corrections Needed
  13. Zoning Review - Corrections Needed
  14. Zoning Review - Corrections Needed
  15. Zoning Review - Reviewed
  16. Final Review - Processing
  17. Final Review - Documents Required
  18. Final Review - Reviewed
  19. Final Review - Payment Needed
  20. Permit Issued

Contractors

  • Tabitha M Sibel

    Rjh Construction

    License
    CGC1515388
    Title
    General Contractor
    Role
    Contractor

    County License & State License Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tabitha M Sibel

    Rjh Construction

    License
    CCC1331967
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License Expired.

  • Robert Lynch

    Third Day Electric Llc

    License
    EC13001947
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License Expired.

  • Timothy D Shatto

    Shatto Heating & Air, Inc.

    License
    CAC057875
    Title
    A/c Class B
    Role
    Subcontractor

Inspections

  1. Jun 15, 2023

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  2. Jun 20, 2023

    Cancelled: Building - Slab

    Inspected by Emaleigh Williams

  3. Jun 20, 2023

    Failed: Building - Slab

    Clean Out Cave In Areas Complete Form Boards, Check With Architect About Transfers Bars Or Wire Chairs.

    Inspected by Troy Crews

  4. Jul 12, 2023

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  5. Jul 12, 2023

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  6. Jul 28, 2023

    Passed: Building - Framing

    Repair Cracked Truss North Porch Area

    Inspected by Troy Crews

  7. Jul 28, 2023

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  8. Jul 28, 2023

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  9. Jul 28, 2023

    Cancelled: Electrical - 1st Underground Rough–In

    Inspected by Troy Crews

  10. Jul 28, 2023

    Cancelled: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  11. Jul 28, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  12. Jul 28, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  13. Aug 3, 2023

    Passed: Building - Insulation

    Inspected by Troy Crews

  14. Aug 4, 2023

    Cancelled: Building - Insulation

    Inspected by Troy Crews

  15. Sep 19, 2023

    Passed: Electrical - Permanent Power

    Need Final Septic Release

    Inspected by Troy Crews

  16. Sep 20, 2023

    Release to power company

    Rec'd Septic Final

    Inspected by Troy Crews

  17. Sep 20, 2023

    Septic Release Inspection

    Inspected by Health Dept

  18. Nov 17, 2023

    Rescheduled 11/21/2023:Building - Final

    Inspected by Troy Crews

  19. Nov 21, 2023

    Cancelled: Building - Final

    Inspected by Troy Crews

  20. Dec 1, 2023

    Passed: Building - Final

    Inspected by Troy Crews

Documents