Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 695 SE CHURCH AVE
LAKE CITY, FL 32025
Parcel #: 14216-001
Acres: 0.15
Owner: Generation Group Llc
Subdivision: Kripners Replat
Zoning:
Flood Zone: X
District: 5
Application #: 60609
Permit #: 000047266
Related Permit:
Submitted: Wednesday, April 19, 2023
Issued: Wednesday, May 17, 2023
Expires: Monday, November 13, 2023
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:
FRONT 2 CORNER SETBACKS MUST BE MET TO MAINTAIN 35' WETLAND SETBACK
LAKE CITY UTLITY CUSTOMER SERVICE NOTES A tap application was approved for water and sewer services. LAKE CITY ZONING NOTES waste pro and driveway permit to be obtained with the City. LAKE CITY CODE ENFORCEMENT CASE NOTES None
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 113.7'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 25' (2nd front)
Setback Side 2 10'
Setbacks Rear 10'
Stories 1
Heated Area (Sqft) 1807
Total Area (Sqft) 2512
Building Height 22
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) x-city
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
3/27/2023 Application pending.
4/19/2023 Application submitted by applicant.
4/19/2023 City of Lake City
4/24/2023 Point Review - Printed-Online Application
4/24/2023 Point Review - Reviewed
5/2/2023 Plan Review - Plumbing Approved
5/2/2023 Plan Review - Mechanical Approved
5/2/2023 Plan Review - Electrical Approved
5/2/2023 Plan Review - Building Approved
5/2/2023 Plan Review - Reviewed
5/2/2023 Zoning Review - Documents Required
5/4/2023 Zoning Review - Documents Required
5/8/2023 Zoning Review - Documents Required
5/9/2023 Zoning Review - Documents Required
5/15/2023 Zoning Review - Reviewed
5/15/2023 Final Review - Reviewed
5/17/2023 Final Review - Reviewed
5/17/2023 Final Review - Payment Needed
5/17/2023 Permit Issued
Contractors
Name/ Business License Title Role
Aaron Nickelson
Aaron Marc Homes
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CBC1258040 Building Contractor Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Donald R Hollingsworth
Holly Electric Inc
EC13005429 Electrical Subcontractor
Stephen M Brisbois
Epic Ac Service (dba) Central Home Heating & Air Llc
CAC1819412 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Documents
File Name Date File Size