Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 1494 SW SANTA FE DR
FORT WHITE, FL 32038
Parcel #: 00641-011
Acres: 0.62
Owner: Futral James H, Futral Cathy C
Subdivision: Three Rivers Estates Unit 6
Zoning: ESA-2
Flood Zone: AE
District: 2
Application #: 56158
Permit #: 000047218
Related Permit:
Submitted: Monday, August 29, 2022
Issued: Thursday, May 11, 2023
Expires: Monday, June 10, 2024
Completed: Monday, June 10, 2024
Status: Completed
Septic Release? Yes
Notes:
**MFE= 34' ELEVATION CERTIFICATE REQUIRED PRIOR TO POWER-- REC'D EXISTING HOME TO BE REMOVED PER APPLICATION
Job Details
Elevation regulation Special Flood Hazard Area
Finished floor requirement 34' One foot above FEMA Map Elevation
Requirement needed By Permanent Power Inspection
Document needed is an Elevation Certificate for Finished Construction
Document receieved Yes
Fema map number 12023C0466C
In floodway Y
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 25'
Stories 2
Heated Area (Sqft) 1305
Total Area (Sqft) 1557
Building Height 14
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0865
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
8/19/2022 Application pending.
9/12/2022 Point Review - On Hold-Incomplete NEEDED *OWNERS PHONE NUMBER *ENVIROMENTAL HEALTH RELEASE - CONTACT 386-758-1058 *SEALED PLANS *ENERGY CODE *MANUAL J *RESIDENTIAL CHECKLIST *SITE PLAN WITH FRONT/BACK SETBACK *TRUSS ENGINEERING *JARVIS & GRADDY UPDATED LICENSE & LIABILITY
9/28/2022 Point Review - On Hold-Incomplete NEEDED: *OWNERS PHONE NUMBER *ENVIROMENTAL HEALTH RELEASE - CONTACT 386-758-1058 *SEALED STRUCTURAL/ARCHITECTURAL PLANS *ENERGY CODE *MANUAL J *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING
10/5/2022 Point Review - On Hold-Incomplete NEEDED: *OWNERS PHONE NUMBER *ENVIROMENTAL HEALTH RELEASE - CONTACT 386-758-1058 *SEALED STRUCTURAL/ARCHITECTURAL PLANS *ENERGY CODE *MANUAL J *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING
10/18/2022 Point Review - On Hold-Incomplete NEEDED: *OWNERS PHONE NUMBER *ENVIROMENTAL HEALTH RELEASE - CONTACT 386-758-1058 *SEALED STRUCTURAL/ARCHITECTURAL PLANS *ENERGY CODE *MANUAL J *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING
10/21/2022 Point Review - On Hold-Incomplete NEEDED: *OWNERS PHONE NUMBER *ENVIROMENTAL HEALTH RELEASE - CONTACT 386-758-1058 *SEALED STRUCTURAL/ARCHITECTURAL PLANS *ENERGY CODE *MANUAL J *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING
10/21/2022 Point Review - Email Sent NEEDED: *OWNERS PHONE NUMBER *ENVIROMENTAL HEALTH RELEASE - CONTACT 386-758-1058 *SEALED STRUCTURAL/ARCHITECTURAL PLANS *ENERGY CODE *MANUAL J *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING
10/21/2022 Point Review - On Hold-Incomplete NEEDED: *OWNERS PHONE NUMBER *ENVIROMENTAL HEALTH RELEASE - CONTACT 386-758-1058 *SEALED STRUCTURAL/ARCHITECTURAL PLANS *ENERGY CODE *MANUAL J *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING
11/21/2022 Point Review - On Hold-Incomplete NEEDED: *ENVIROMENTAL HEALTH RELEASE - CONTACT 386-758-1058 *SEALED STRUCTURAL/ARCHITECTURAL PLANS *ENERGY CODE *MANUAL J *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING
3/1/2023 Point Review - Printed-Online Application NEEDED: *ARCHITECT/ENGINEER CELL COMPLETED *RESIDENTIAL CHECKLIST-- MISSING SQ FT
3/1/2023 Point Review - Reviewed NEEDED: *ARCHITECT/ENGINEER CELL COMPLETED *RESIDENTIAL CHECKLIST-- MISSING SQ FT
3/6/2023 Plan Review - Documents Required NEED: *NO FLOOR PLAN OR ELECTRICIAL PLAN.
3/13/2023 Plan Review - Building Approved
3/13/2023 Plan Review - Electrical Approved
3/13/2023 Plan Review - Mechanical Approved
3/13/2023 Plan Review - Plumbing Approved
3/13/2023 Plan Review - Fuel/Gas Approved
3/13/2023 Plan Review - Reviewed
3/15/2023 Zoning Review - Reviewed NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
3/15/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
3/20/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
3/23/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
3/29/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/3/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/5/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/10/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/12/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/13/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/17/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/20/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/24/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/25/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
4/27/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
5/1/2023 Final Review - Documents Required NEED: -0' RISE FROM ENGINEER -ELEVATION CERTIFICATE
5/3/2023 Final Review - Reviewed NEED: -ELEVATION CERTIFICATE REQUIRED FOR PERMANENT POWER
5/11/2023 Final Review - Reviewed -ELEVATION CERTIFICATE REQUIRED PRIOR TO PERMANENT POWER INSPECTION BEING GRANTED
5/11/2023 Final Review - Payment Needed -ELEVATION CERTIFICATE REQUIRED PRIOR TO PERMANENT POWER INSPECTION BEING GRANTED
5/11/2023 Final Review - Payment Needed -ELEVATION CERTIFICATE REQUIRED PRIOR TO PERMANENT POWER INSPECTION BEING GRANTED
5/11/2023 Permit Issued Permit #000047218 created and approved.
3/26/2024 Final Review - Payment Needed -ELEVATION CERTIFICATE REQUIRED PRIOR TO PERMANENT POWER INSPECTION BEING GRANTED
Contractors
Name/ Business License Title Role
Dustin Busscher
Busscher Enterprises Llc Dba Jbc Builders
CBC1263910 Cert. Building Contractor
Robert Jarvis
Jarvis Heat And Air Llc
CAC1816766 Class "b" A/c Subcontractor
Curtis Graddy
Curtis Graddy Plumbing Llc
CFC043064 Plumbing Contractor Subcontractor
Lewis G Walker
Lewis Walker Roofing Inc
CCC1333551 Cert. Roofing Subcontractor
Alaina Perry
North Florida Maintenance And Repair Services Llc
ER13016315 Reg. Electrical Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Monolithic Slab Matt Forsyth 6/27/2023
Passed: Engineering - Setbacks Matt Forsyth 6/27/2023
Passed: Building - Vertical Cells/Columns Matt Forsyth 7/31/2023
Cancelled: Building - Wall Sheathing Anthony Aslan 11/21/2023
Failed: Building - Roof Decking Spray Foam Insulation No Way To Verify Need Engineer Letter Anthony Aslan 11/21/2023
Failed: Building - Ext Strapping/Wall Sheathing Nails Missing Sheating Loose In Multiple Places Needs To Be Corrected Anthony Aslan 11/21/2023
Failed: Building - Framing No Safety Railling On Rear Stairs & Porch Needs To Be Corrected Immediately spray Foam Need Engineer Letter Anthony Aslan 11/21/2023
Cancelled: Building - Rated Assembly Fastening Anthony Aslan 11/21/2023
Failed: Building - Insulation No Safety Railling On Rear Stairs & Porch Needs To Be Corrected Immediately Anthony Aslan 11/21/2023
Cancelled: Building - Strapping Anthony Aslan 11/21/2023
Failed: Mechanical - Rough In No Safety Railling On Rear Stairs & Porch Needs To Be Corrected Immediately ducts Missing Proper Strapping exhaust Fans Not Installed fresh Air Missing Proper Damper And Needs To Be Installed At Unit For Access To Damper, Fresh Air Requires A Filter Anthony Aslan 11/21/2023
Failed: Electrical - 2nd Rough-In No Safety Railling On Rear Stairs & Porch Needs To Be Corrected Immediately Anthony Aslan 11/21/2023
Failed: Plumbing/Gas - 2nd Rough-In No Safety Railling On Rear Stairs & Porch Needs To Be Corrected Immediately Anthony Aslan 11/21/2023
Failed: Building - Ext Strapping/Wall Sheathing Strapping Is Being Redone Matt Forsyth 11/30/2023
Failed: Building - Insulation Second Roughs Have To All Be Complete Before Passing An Insulation Inspection Including Framing Matt Forsyth 11/30/2023
Failed: Building - Framing Not Complete Matt Forsyth 11/30/2023
Passed: Building - Roof Decking Matt Forsyth 11/30/2023
Passed: Electrical - 2nd Rough-In Matt Forsyth 11/30/2023
Passed: Mechanical - Rough In Matt Forsyth 11/30/2023
Failed: Plumbing/Gas - 2nd Rough-In Need Water Test For Upper Floor Dwv Matt Forsyth 11/30/2023
Passed: Building - Ext Strapping/Wall Sheathing Extra Strapping Installed Matt Forsyth 12/6/2023
Passed: Building - Framing H2.5 Truss Tail Strapping Matt Forsyth 12/6/2023
Passed: Plumbing/Gas - 2nd Rough-In Upper Floor Dwv Water Tested Will Need Shower Liner Inspection When Ready Matt Forsyth 12/6/2023
Passed: Building - Insulation Matt Forsyth 12/6/2023
Passed: Electrical - Permanent Power Need Septic Release To Release Power Matt Forsyth 3/27/2024
Septic Release Inspection Pending Corrected Elevation Certificate -- Do Not Release Power Until Rec'd--rec'd Health Dept 4/2/2024
Release to power company Melissa Garber 4/9/2024
Failed: Building - Final Not Ready For Final Matt Forsyth 5/30/2024
Passed: Building - Final Co Pending Install Of Two Smoke Detectors One In Hall, One In Primary Bedroom. Existing House To Become Storage Or Pavillion No Living Quarters Power Coming From Main Dwelling. Troy Crews 6/6/2024
Passed: Building - Final Pictures Of Smoke Detectors Installed Sent. Troy Crews 6/10/2024
Documents
File Name Date File Size
Oves0tkf.hw5.pdf 2025.07.14 1.07MB
J4jmwtzu.uev.pdf 2025.07.14 1.17MB
Ea5pnbud.qas.pdf 2025.07.14 500.54kB
Lidar 56158 2023-03-15 10.57.41.350.pdf 2025.07.05 90.95kB
Site Plan 20220822 142134.pdf 2025.07.05 55.01kB
Energy Code Forms 20221207 083655.pdf 2025.07.05 91.33kB
Recorded Notice Of Commencement 20220901 112640.pdf 2025.07.05 86.72kB
1494 Sw Santa Fe Dr.pdf 2025.07.05 124.96kB
Fw_ Futural - Elevation Certificate Email.pdf 2025.07.05 128.12kB
Owner And Contractor Signature Page 20220822 140329.pdf 2025.07.05 153.39kB
Manual J Forms 20221207 083440.pdf 2025.07.05 117.23kB
Subcontractor Form 20220909 102247.pdf 2025.07.05 251.43kB
Property Appraiser Parcel Details Printed Page 20220822 142133.pdf 2025.07.05 251.65kB
Futral Electrician Change Request Rec'd 6.7.24.pdf 2025.07.05 403.21kB
Residential Or Commercial Checklist 20230215 095336.pdf 2025.07.04 963.13kB
Futral One Foot Rise Certification Attestation_ss.pdf 2025.07.04 737.89kB
Change Of Electrician For 3 Of Our Jobs.pdf 2025.07.04 2.25MB
Product Approval Code Specifications Form 20220826 133612.pdf 2025.07.04 3.68MB
Structural Engineering And Wind Load Calculations 20230215 094801.pdf 2025.07.04 5.30MB
Reviewed Structural Engineering And Wind Load Calculations 56158 2023-03-13 07.59.42.306.pdf 2025.07.04 5.34MB
Architectural Plans 20230306 110947.pdf 2025.07.04 6.76MB
Reviewed Architectural Plans 56158 2023-03-13 07.59.40.119.pdf 2025.07.04 6.79MB
Residential Or Commercial Checklist 20230302 104017.pdf 2025.07.04 1.89MB
Blower Door Frutal 2024-06-07 07.14.05.149.jpg 2025.07.03 1.88MB
Epl Card.pdf 2025.06.23 29.81kB
Certificate Of Occupancy 20240610.pdf 2025.06.23 53.33kB
Termite Treatment_initial 20240520 120200.pdf 2025.06.22 53.81kB
Elevation Certificate For Finished Construction 20240426 025849.pdf 2025.06.21 1.97MB
Win_20230627_16_14_03_pro 2023-06-27 16.15.07.143.jpg 2025.06.20 217.56kB
Blower Door Test Results 20240605 091056.pdf 2024.06.05 2.29kB
Termite Certificate_final 20240604 133308.pdf 2024.06.04 457.08kB
Power Release-release To Power Company 20240409.pdf 2024.04.09 38.92kB
Recorded Deed 20220822 140329.pdf 2023.12.23 83.24kB
Septic Approval Paperwork 20230123 102520.pdf 2023.12.23 1.29MB
Original Permit 20230511.pdf 2023.05.11 46.40kB