Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 849 SW DAWN LN
LAKE CITY, FL 32024
Parcel #: 09620-001
Acres: 17.02
Owner: Seraballs Stephen,
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 59350
Permit #: 000047188
Related Permit: Culvert Waiver: 000047189
Submitted: Monday, March 6, 2023
Issued: Wednesday, May 10, 2023
Expires: Monday, February 17, 2025
Completed:
Status: Permit Issued
Septic Release? No
Notes:
MFE= 1' ABOVE THE ROAD
Job Details
This is the construction of a Single Family Dwelling
If Other, explain the use of the structure. PEMB
Heated Area (Sqft) 1980
Total Area (Sqft) 1980
Stories 1
Building Height 17
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 23-0130
Service Amps 200
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0485C
In floodway N
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
3/6/2023 Application pending.
3/6/2023 Application submitted by applicant.
3/22/2023 Plan Review - Corrections Needed NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY **NO EGRESS WINDOWS IN BEDROOM **NO MANUAL J UPLOADED, ONLY ENERGY FORM
3/27/2023 Plan Review - Corrections Needed NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY **NO EGRESS WINDOWS IN BEDROOM
4/3/2023 Plan Review - Corrections Needed NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY **NO EGRESS WINDOWS IN BEDROOM
4/4/2023 Plan Review - Corrections Needed NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY **NO EGRESS WINDOWS IN BEDROOM
4/11/2023 Plan Review - Corrections Needed NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY **NO EGRESS WINDOWS IN BEDROOM
4/12/2023 Point Review - Printed-Online Application NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY **NO EGRESS WINDOWS IN BEDROOM
4/17/2023 Plan Review - On Hold-Incomplete NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY **NO EGRESS WINDOWS IN BEDROOM
4/24/2023 Plan Review - On Hold-Incomplete NEED: **NO EGRESS WINDOW IN BEDROOM** **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY (NICK SENT EMAIL FOR RISK CATEGORY)
5/1/2023 Plan Review - Building Approved NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY (NICK SENT EMAIL FOR RISK CATEGORY)
5/1/2023 Plan Review - Electrical Approved NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY (NICK SENT EMAIL FOR RISK CATEGORY)
5/1/2023 Plan Review - Mechanical Approved NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY (NICK SENT EMAIL FOR RISK CATEGORY)
5/1/2023 Plan Review - Plumbing Approved NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY (NICK SENT EMAIL FOR RISK CATEGORY)
5/1/2023 Plan Review - Reviewed NEED: **STRUCTURAL PLANS RISK CATEGORY 1 NOT RATED FOR SINGLE FAMILY (NICK SENT EMAIL FOR RISK CATEGORY)
5/3/2023 Zoning Review - Reviewed NEED:
5/3/2023 Final Review - Reviewed NEED:
5/8/2023 Final Review - Reviewed
5/8/2023 Final Review - Payment Needed
5/10/2023 Permit Issued Permit #000047188 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Fill Waste Pipe With Water For Test Prior To Pouring Slab. Troy Crews 6/12/2023
Cancelled: Electrical - Permanent Power Melissa Garber 6/16/2023
Passed: Electrical - Temporary Service Troy Crews 6/20/2023
Release to power company Troy Crews 6/20/2023
Passed: Building - Monolithic Slab Troy Crews 6/20/2023
Passed: Engineering - Setbacks Troy Crews 6/20/2023
Passed: Building - Framing Metal Building Shell Installed And Bolted Down Troy Crews 8/16/2023
Rescheduled 1/30/2024:Building - Framing Emaleigh Williams 1/25/2024
Rescheduled 1/30/2024:Electrical - 2nd Rough-In Emaleigh Williams 1/25/2024
Rescheduled 1/30/2024:Plumbing/Gas - 2nd Rough-In Emaleigh Williams 1/25/2024
Rescheduled 1/30/2024:Plumbing/Gas - Tub Set/Shower Pan Emaleigh Williams 1/25/2024
Passed: Building - Framing Troy Crews 1/30/2024
Passed: Electrical - 2nd Rough-In Troy Crews 1/30/2024
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 1/30/2024
Passed: Plumbing/Gas - Tub Set/Shower Pan Troy Crews 1/30/2024
Passed: Building - Insulation Troy Crews 2/27/2024
Passed: Engineering - Spot Check Readty For Sheetrock Troy Crews 8/21/2024
Documents
File Name Date File Size
Subcontractor Form 20230306 135105.pdf 2023.12.23 283.03kB
911 Address Form 20230306 140326.pdf 2023.12.23 281.90kB
Architectural Plans 20230306 133856.pdf 2023.12.23 1.92MB
Manual J Forms 20230306 134158.pdf 2023.12.23 277.96kB
Lidar 59350 2023-05-02 12.39.41.923.pdf 2023.12.23 120.70kB
Power Release-electrical-temporary Service 20230620.pdf 2023.12.23 38.87kB
Structural Engineering And Wind Load Calculations 20230306 133857.pdf 2023.12.23 2.21MB
Architectural Plans 20230425 165739.pdf 2023.12.23 718.58kB
Residential Or Commercial Checklist 20230306 140326.pdf 2023.12.23 943.32kB
59350 Zoning 2023-05-03 08.50.38.48.pdf 2023.12.23 66.97kB
Recorded Deed 20230306 133639.pdf 2023.12.23 98.99kB
Property Appraiser Parcel Details Printed Page 20230306 134159.pdf 2023.12.23 198.53kB
Fwd_ Risk Catogory Change 59350 2023-04-19 12.06.36.750.pdf 2023.12.23 180.05kB
Owner Disclosure Statement 20230307 130004.pdf 2023.12.23 208.43kB
Subcontractor Form 20230306 134915.pdf 2023.12.23 208.23kB
Recorded Notice Of Commencement 20230510 115347.pdf 2023.12.23 378.67kB
Manual J Forms 20230322 170807.pdf 2023.12.23 256.27kB
Original Permit 20230510.pdf 2023.12.23 45.07kB
Energy Code Forms 20230306 134158.pdf 2023.12.23 277.96kB
New Egress Window.pdf 2023.12.23 203.42kB
Site Plan 20230306 133857.pdf 2023.12.23 368.16kB
Product Approval Code Specifications Form 20230306 133856.pdf 2023.12.23 307.08kB
Septic Approval Paperwork 20230306 133857.pdf 2023.12.23 1.33MB
Owner And Contractor Signature Page 20230306 133639.pdf 2023.12.23 101.24kB