Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Mobile Home Permit
Address 500 NW DREAMER LN
WHITE SPRINGS, FL 32096
Parcel #: 01642-001
Acres: 10.13
Owner: Roche Edwin S, Roche Merri L
Subdivision:
Zoning: A-3
Flood Zone: X
District: 1
Application #: 58826
Permit #: 000047035
Related Permit:
Submitted: Wednesday, January 25, 2023
Issued: Friday, April 21, 2023
Expires: Wednesday, July 19, 2023
Completed: Wednesday, July 19, 2023
Status: Completed
Septic Release? Yes
Notes:
MFE= 1' ABOVE THE ROAD ONE UNIT REMOVED ONLY ONE ONSITE AT THIS TIME REPLACING SECOND UNIT
Job Details
Mobile Home is a: Double Wide
Year Built 2023
Width (Ft.In) 32
Length (Ft.In) 60
Wind Zone? 2
Serial # DISH11832GA-A/B
Installation Decal # 96484
Service Amps 200
Residential or Commercial Use? Residential
Driveway access to home: Existing Drive
Are you applying for a 5 year temporary permit? No
Septic # (00-0000) or (X00-000) 23-0063
Dev Permit # F023-
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0159D
In floodway N
Review Notes
1/25/2023 Application pending.
1/25/2023 Application submitted by applicant.
2/2/2023 Point Review - Reviewed NEEDED * CONFIRMATION HOW MANY HOMES ARE CURRENTLY ON PROPERTY - IS THIS A REPLACEMENT? * STUP MAY BE REQUIRED.
2/2/2023 Point Review - Printed-Online Application NEEDED * CONFIRMATION HOW MANY HOMES ARE CURRENTLY ON PROPERTY - IS THIS A REPLACEMENT? * STUP MAY BE REQUIRED.
2/3/2023 Plan Review - Reviewed NEEDED * CONFIRMATION HOW MANY HOMES ARE CURRENTLY ON PROPERTY - IS THIS A REPLACEMENT? * STUP MAY BE REQUIRED.
2/6/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME
2/10/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME
2/13/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME
2/20/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME
2/23/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
2/27/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/3/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/6/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/7/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/13/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/17/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/20/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/21/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/23/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
3/29/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
4/3/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
4/5/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
4/10/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
4/12/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
4/13/2023 Zoning Review - Corrections Needed NEEDED NEED TO REMOVE ONE UNIT PRIOR TO PERMIT, SECOND UNIT TO BE REMOVED 30 DAYS AFTER C.O. ISSUED FOR NEW HOME ADVISE WHEN UNIT IS MOVED SO WE CAN COMPLETE PERMIT
4/14/2023 Zoning Review - Reviewed
4/14/2023 Final Review - Reviewed
4/18/2023 Final Review - Reviewed
4/18/2023 Final Review - Payment Needed
4/21/2023 Permit Issued Permit #000047035 created and approved.
Contractors
Name/ Business License Title Role
Ronald "ryan" Norris
Norris Mobile Home Mover & Set Up
County License & State License Expired.
IH1135009 Mh Installer (ih) Contractor
Steven M Mollman
Mollman Air Conditioning And Refrigeration Llc
CAC1819696 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Mobile Home - In County Pre-Mobile Home before set-up Only One Mobile Home On Property At This Time 4-14-23 Troy Crews 4/14/2023
Septic Release Inspection Health Dept 6/6/2023
Passed: Mobile Home - Mobile Home Set-Up Final Matt Forsyth 7/19/2023
Release to power company Matt Forsyth 7/19/2023
Passed: Engineering - Setbacks Matt Forsyth 7/19/2023