Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 1802 NW FRONTIER DR
LAKE CITY, FL 32055
Parcel #: 02310-132
Acres: 0.46
Owner: Keith Eric Archbold
Subdivision: Village On The Green
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 59159
Permit #: 000047022
Related Permit: Culvert Waiver: 000047023
Submitted: Thursday, February 16, 2023
Issued: Thursday, April 20, 2023
Expires: Wednesday, August 21, 2024
Completed: Wednesday, August 21, 2024
Status: Completed
Septic Release? Yes
Notes:
**WE NEED CONFIRMATION THAT THE MFE WILL BE A MINIMUM 1' ABOVE THE ROAD. IF THIS CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
LAKE CITY UTLITY CUSTOMER SERVICE NOTES The Utility Department approved the Tap Application for water and natural gas services.
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0280D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 2'5
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 2
Heated Area (Sqft) 2552
Total Area (Sqft) 3995
Building Height 24
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 23-0243
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
2/16/2023 Application pending.
2/16/2023 Application submitted by applicant.
2/16/2023 City of Lake City Utilities Notified
2/17/2023 Point Review - On Hold-Incomplete
3/7/2023 Point Review - Printed-Online Application
3/15/2023 Plan Review - Building Approved
3/15/2023 Plan Review - Electrical Approved
3/15/2023 Plan Review - Mechanical Approved
3/15/2023 Plan Review - Plumbing Approved
3/15/2023 Plan Review - Fuel/Gas Approved
3/15/2023 Plan Review - Reviewed
3/17/2023 Zoning Review - Reviewed
3/20/2023 Final Review - Documents Required
3/28/2023 Final Review - Documents Required
3/29/2023 Final Review - Documents Required
3/30/2023 Final Review - Documents Required
4/4/2023 Final Review - Documents Required
4/10/2023 Final Review - Documents Required
4/13/2023 Final Review - Documents Required
4/19/2023 Final Review - Reviewed
4/19/2023 Final Review - Payment Needed
4/20/2023 Permit Issued
6/26/2024 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Bradley Franks
Bradley Franks Construction Llc
County License & State License & Workers Comp Expired.
RG291103874 General Contractor Contractor
John D Williams
John Williams Plumbing Inc
CFC056961 Plumbing Contractor Subcontractor
Oscar Gray
Dependable Heating A/c & Electrical Contractor
EC0001471 Electrical Contractor Subcontractor
Anthony R Franks
Lane Heating & Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Failed: Building - Footer Need Compaction Done On Dirt Work Matt Forsyth 5/9/2023
Passed: Engineering - Setbacks Matt Forsyth 5/9/2023
Cancelled: Engineering - Setbacks Matt Forsyth 5/10/2023
Passed: Building - Footer Compaction Rec Matt Forsyth 5/10/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 6/14/2023
Passed: Building - Slab Troy Crews 6/20/2023
Passed: Electrical - Temporary Service Matt Forsyth 7/13/2023
Release to power company Matt Forsyth 7/13/2023
Passed: Building - Lintel/Tie Beam Troy Crews 8/22/2023
Passed: Building - Roof Decking Matt Forsyth 9/22/2023
Passed: Building - Framing Windows And Doors Not In Stalled Yet Matt Forsyth 10/3/2023
Passed: Building - Wall Sheathing Matt Forsyth 10/3/2023
Passed: Electrical - 2nd Rough-In Anthony Aslan 11/22/2023
Passed: Mechanical - Rough In Missing Screws In Kitchen Exhaust Pipe vaccum Pipes Missing Nail Guards Anthony Aslan 11/22/2023
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 11/22/2023
Passed: Building - Insulation Matt Forsyth 12/7/2023
Failed: Electrical - Permanent Power Need Ground Rod For Bonding Septic Also Needs To Be Released Matt Forsyth 5/29/2024
Passed: Electrical - Permanent Power Matt Forsyth 5/30/2024
Release to power company Matt Forsyth 5/30/2024
Passed: Building - Final Need Septic Release To Complete Permit And Release Certificate Of Occupancy Matt Forsyth 8/14/2024
Release to power company Melissa Garber 8/21/2024
Certificate-Release Certificate Matt Forsyth 8/21/2024
Septic Release Inspection Health Dept 8/21/2024
Documents
File Name Date File Size