Storage Building
Permit
| Application #: | 59457 |
| Permit #: |
000046921 |
| Related Permit: |
|
| Submitted: | Tuesday, March 14, 2023 |
| Issued: | Monday, April 10, 2023 |
| Expires: | Tuesday, August 8, 2023 |
| Completed: | Tuesday, August 8, 2023 |
| Status: |
Completed |
| Septic Release? |
Yes |
Notes
NON-HABITABLE STRUCTURE
Job Details
| Elevation regulation |
Accessory Use |
| Finished floor requirement |
Non-Habitable Structure |
| Fema map number |
12023C0395C |
| In floodway |
N |
| Type of Structure |
Storage Building |
| Commercial or Residential? |
Residential |
| Total Area (Sqft) |
1820 |
| Septic# (00-0000) or (X00-000) |
x23-057 |
| Setbacks Front |
30 |
| Setback Side 1 |
25 |
| Setback Side 2 |
25 |
| Setback Rear |
25 |
| Building Code Construction Type |
III |
| Building Code Element |
B |
| Building Code Occupancy Types |
Storage |
| Occupancy Use Title |
non habitable storage |
| Dev Permit # |
F023- |
| Building Code Edition |
2020 Florida Building Code 7th Edition and 2017 National Electrical Code |
| Building Height |
10 |
| Building Length |
26' |
| Building Width |
70' |
Review Notes
| 3/15/2023 |
Point Review - Printed-Online Application |
| 3/17/2023 |
Plan Review - Reviewed |
| 3/20/2023 |
Zoning Review - Reviewed |
| 3/20/2023 |
Final Review - Documents Required |
| 4/6/2023 |
Final Review - Reviewed |
| 4/6/2023 |
Final Review - Payment Needed |
| 4/10/2023 |
Permit Issued |
Contractors
| Name / Business |
License |
Title |
Role |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Septic Release Inspection |
|
Health Dept |
4/5/2023 |
| Passed: Building - Slab |
Steel In Deep Footings, Wire In Slab, Electric Bond To Steel Rebar And 3 Inch Electric Conduit Turned Up In Slab |
Gary Pitzer |
4/19/2023 |
| Failed: Electrical - Permanent Power |
No Electrical Equipment At Site |
Gary Pitzer |
7/24/2023 |
| Passed: Electrical - 1st Underground Rough–In |
Underground And Steel Bond Was Completed With Slab |
Gary Pitzer |
7/24/2023 |
| Failed: Building - Final |
No Access |
Gary Pitzer |
7/24/2023 |
| Electrical -Service Upgrade Final |
Service For Storage Building Only |
Gary Pitzer |
8/8/2023 |
| Passed: Building - Final |
Storage Building |
Gary Pitzer |
8/8/2023 |
| Release to power company |
|
Melissa Garber |
8/9/2023 |