Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 372 SW TARA CT
FORT WHITE, FL 32038
Parcel #: 03745-309
Acres: 5.01
Owner: Timothy Colbern
Subdivision: Sunview Estates Addition
Zoning: ESA-2
Flood Zone: X
District: 2
Application #: 60637
Permit #: 000046912
Related Permit:
Submitted: Thursday, April 6, 2023
Issued: Thursday, April 6, 2023
Expires: Friday, April 14, 2023
Completed: Friday, April 14, 2023
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Finished floor requirement
Fema map number 12023C0390C
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Reroof mobile home including tear off of old shingles, replacing plywood if necessary, then 2 ply synthetic dry in. Tamko Heritage Shingles.
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 30
No. of Stories 1
Roof Pitch 2:12 to 4:12
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL18355-R8
Product Manufacturer tamko
Product Description heritage shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Unvented
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
3/28/2023 Application pending.
4/6/2023 Application submitted by applicant.
4/6/2023 Final Review - Corrections Needed NEEDED * OWNERS PHONE NUMBER * PAULA E KENNEDY UPDATED WORKERS COMP
4/6/2023 Final Review - Payment Needed
4/6/2023 Permit Issued Permit #000046912 created and approved.
Contractors
Name/ Business License Title Role
Paula E Kennedy
Gainesville Roofing & Co Inc
County License & State License & Workers Comp Expired.
CCC1328678 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Please Be Advised We Are To See In Progress Inspection. Please Very Good Pictures Of The Project Gary Pitzer 4/12/2023
Passed: Re-Roof - Final Gary Pitzer 4/14/2023