Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 262 SW OAK WAY
LAKE CITY, FL 32025
Parcel #: 09116-128
Acres: 5.01
Owner: Foxx Ronnie, Foxx Jocelyn
Subdivision: Hills At Rose Creek Phase 1
Zoning: A-3
Flood Zone: X
District: 4
Application #: 59175
Permit #: 000046869
Related Permit: Culvert: 000046870
Submitted: Tuesday, February 28, 2023
Issued: Thursday, March 30, 2023
Expires: Thursday, November 30, 2023
Completed: Thursday, November 30, 2023
Status: Completed
Septic Release? Yes
Notes:

Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2550
Total Area (Sqft) 4022
Stories 1
Building Height 22
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 23-0030
Service Amps 200
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0384D
In floodway Y
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Review Notes
2/17/2023 Application pending.
2/28/2023 Application submitted by applicant.
3/15/2023 Point Review - Printed-Online Application
3/23/2023 Plan Review - Building Approved
3/23/2023 Plan Review - Electrical Approved
3/23/2023 Plan Review - Mechanical Approved
3/23/2023 Plan Review - Plumbing Approved
3/23/2023 Plan Review - Fuel/Gas Approved
3/23/2023 Plan Review - Reviewed
3/24/2023 Zoning Review - Reviewed
3/24/2023 Final Review - Reviewed
3/29/2023 Final Review - Payment Needed
3/30/2023 Permit Issued Permit #000046869 created and approved.
Contractors
Name/ Business License Title Role
Bryan Zecher
Bryan Zecher Construction Inc
CBC054575 Cert.building Contractor Contractor
Donald R Hollingsworth
Holly Electric Inc
EC13005429 Electrical Subcontractor
Anthony R Franks
Lane Heating & Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Robert Ogles
Ogles Roofing & Construction Llc
CCC1328699 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Smith, Blake 4/3/2023
Passed: Building - Footer Foyer Steer Bonded, Long Tail Gary Pitzer 4/5/2023
Passed: Engineering - Setbacks Gary Pitzer 4/5/2023
Passed: Electrical - Temporary Service Gary Pitzer 4/6/2023
Release to power company Gary Pitzer 4/6/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Drains And Vents Only, No Water Or Gas Gary Pitzer 4/27/2023
Passed: Building - Slab Plastic Down,taped And Steel Gary Pitzer 5/9/2023
Passed: Building - Wall Sheathing Gary Pitzer 6/28/2023
Passed: Building - Roof Decking Gary Pitzer 6/28/2023
Passed: Building - Framing Gary Pitzer 7/14/2023
Passed: Electrical - 2nd Rough-In Gary Pitzer 8/1/2023
Passed: Mechanical - Rough In Gary Pitzer 8/1/2023
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 8/1/2023
Passed: Building - Insulation Foam Walls And Roof, Draft Stopping In Place Gary Pitzer 8/7/2023
Passed: Building - Lath/Stucco Gary Pitzer 8/21/2023
Failed: Electrical - Permanent Power Need Drive Inspection, Gary Pitzer 10/16/2023
Septic Release Inspection Health Dept 10/27/2023
Passed: Electrical - Permanent Power Do Not Release Till Drive Inspection Is Complete Gary Pitzer 11/2/2023
Passed: Engineering - Final Driveway Smith, Blake 11/6/2023
Release to power company Melissa Garber 11/7/2023
Passed: Building - Final House Only Gary Pitzer 11/30/2023
Documents
File Name Date File Size
Reviewed Truss Engineering 59175 2023-03-23 13.13.37.300.pdf 2023.12.23 3.82MB
Product Approval Code Specifications Form 20230217 124540.pdf 2023.12.23 539.92kB
Reviewed Architectural Plans 59175 2023-03-23 13.13.38.222.pdf 2023.12.23 938.85kB
Img_0069 2023-05-12 09.18.41.324.jpg 2023.12.23 1.51MB
Recorded Deed 20230217 122819.pdf 2023.12.23 81.37kB
Septic Approval Paperwork 20230222 202223.pdf 2023.12.23 1.18MB
Termite Certificate_final 20231129 145049.pdf 2023.12.23 91.77kB
Termite Treatment_initial 20231129 145050.pdf 2023.12.23 119.99kB
Power Release-electrical-permanent Power 20231016.pdf 2023.12.23 38.99kB
Power Release-electrical-temporary Service 20230406.pdf 2023.12.23 38.86kB
Residential Or Commercial Checklist 20230227 154823.pdf 2023.12.23 2.68MB
Recorded Notice Of Commencement 20230227 154823.pdf 2023.12.23 91.10kB
Subcontractor Form 20230220 111424.pdf 2023.12.23 546.42kB
Power Release-release To Power Company 20231107.pdf 2023.12.23 39.00kB
Lidar 59175 2023-03-24 14.52.37.769.pdf 2023.12.23 124.96kB
Owner And Contractor Signature Page 20230228 144115.pdf 2023.12.23 631.61kB
911 Address Form 20230217 124540.pdf 2023.12.23 173.27kB
Reviewed Structural Engineering And Wind Load Calculations 59175 2023-03-23 13.13.35.925.pdf 2023.12.23 5.75MB
Original Permit 20230330.pdf 2023.12.23 136.96kB
Manual J Forms 20230223 185127.pdf 2023.12.23 269.17kB
Architectural Plans 20230222 202222.pdf 2023.12.23 1.23MB
Property Appraiser Parcel Details Printed Page 20230220 111338.pdf 2023.12.23 539.50kB
Energy Code Forms 20230223 185126.pdf 2023.12.23 536.01kB
Truss Engineering 20230222 202223.pdf 2023.12.23 3.47MB
Certificate Of Occupancy 20231130.pdf 2023.12.23 53.63kB
Structural Engineering And Wind Load Calculations 20230225 205511.pdf 2023.12.23 5.73MB
Site Plan 20230220 111338.pdf 2023.12.23 357.61kB