| Application #: | 59367 |
| Permit #: |
000046856 |
| Related Permit: |
|
| Submitted: | Tuesday, March 7, 2023 |
| Issued: | Wednesday, March 29, 2023 |
| Expires: | Wednesday, November 1, 2023 |
| Completed: | Wednesday, November 1, 2023 |
| Status: |
Completed |
| Septic Release? |
Yes |
Notes
MFE= 1' ABOVE THE ROAD
| Elevation regulation |
Minimum Requirement |
| Finished floor requirement |
One foot above the road |
| Fema map number |
12023C0381D |
| In floodway |
N |
| This is the construction of a |
Single Family Dwelling |
| Setbacks Front |
25 |
| Setback Side 1 |
10 |
| Setback Side 2 |
10 |
| Setbacks Rear |
15 |
| Stories |
1 |
| Heated Area (Sqft) |
1600 |
| Total Area (Sqft) |
2283 |
| Building Height |
19 |
| Building Code Construction Type |
V |
| Building Code Element |
B |
| Building Code Occupancy Types |
Residential |
| Occupancy Use Title |
single family dwelling |
| Building Code Edition |
2020 Florida Building Code 7th Edition and 2017 National Electrical Code |
| Septic# (00-0000) or (X00-000) |
22-0625 |
| Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
| 3/13/2023 |
Plan Review - Building Approved |
| 3/13/2023 |
Plan Review - Electrical Approved |
| 3/13/2023 |
Plan Review - Mechanical Approved |
| 3/13/2023 |
Plan Review - Plumbing Approved |
| 3/13/2023 |
Plan Review - Fuel/Gas Approved |
| 3/13/2023 |
Plan Review - Reviewed |
| 3/15/2023 |
Zoning Review - Reviewed |
| 3/15/2023 |
Point Review - Reviewed |
| 3/15/2023 |
Final Review - Reviewed |
| 3/15/2023 |
Final Review - Reviewed |
| 3/15/2023 |
Final Review - Payment Needed |
| 3/29/2023 |
Permit Issued |
| Name / Business |
License |
Title |
Role |
Brian T Giebeig Trent Giebeig Construction,inc.
|
CRC1330693 |
Residential Contractor |
Contractor |
Everton D Ruddock D&s Lighting Inc
|
EC13003800 |
Electrical Contractor |
Subcontractor |
Derrick L Williams Dl Williams Heating & Cooling Llc
|
CAC1816913 |
Class "b" A/c Contractor |
Subcontractor |
Kenneth R Roche Ken Roche Plumbing Inc Dba Plumbing Now
|
CFC1426527 |
Plumbing Contractor |
Subcontractor |
| Inspection |
Notes |
Performed By |
Date |
| Passed: Electrical - Temporary Service |
|
Anthony Aslan |
6/21/2023 |
| Release to power company |
|
Anthony Aslan |
6/21/2023 |
| Passed: Building - Footer |
|
Anthony Aslan |
6/21/2023 |
| Passed: Engineering - Setbacks |
|
Anthony Aslan |
6/21/2023 |
| Passed: Plumbing/Gas - 1st Underground Rough–In |
|
Anthony Aslan |
6/27/2023 |
| Passed: Building - Slab |
|
Anthony Aslan |
6/30/2023 |
| Passed: Building - Roof Decking |
|
Anthony Aslan |
8/1/2023 |
| Passed: Building - Wall Sheathing |
|
Anthony Aslan |
8/1/2023 |
| Passed: Building - Framing |
T02 Missing Engineering |
Anthony Aslan |
8/15/2023 |
| Failed: Mechanical - Rough In |
Incomplete |
Anthony Aslan |
8/28/2023 |
| Passed: Electrical - 2nd Rough-In |
|
Anthony Aslan |
8/28/2023 |
| Failed: Plumbing/Gas - 2nd Rough-In |
Tub Over Flow Not Piped In, No Water In Tub |
Anthony Aslan |
8/28/2023 |
| Passed: Plumbing/Gas - 2nd Rough-In |
|
Anthony Aslan |
8/31/2023 |
| Passed: Building - Framing |
|
Anthony Aslan |
9/1/2023 |
| Passed: Mechanical - Rough In |
|
Anthony Aslan |
9/1/2023 |
| Passed: Building - Insulation |
|
Anthony Aslan |
9/7/2023 |
| Passed: Electrical - Permanent Power |
Need Septic Release
need Driveway Release |
Anthony Aslan |
10/6/2023 |
| Release to power company |
Rec'd Septic And Drive |
Anthony Aslan |
10/12/2023 |
| Septic Release Inspection |
|
Health Dept |
10/12/2023 |
| Failed: Building - Final |
No Disconnect On Water Heater(corrected)
master Toilet Not Connected (corrected)
outlet To The Left Not Gfci (corrected)
no Blower Door (rec'd) |
Anthony Aslan |
10/30/2023 |
| Passed: Building - Final |
|
Anthony Aslan |
11/1/2023 |