Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 344 NW SPRING HOLLOW BLVD
LAKE CITY, FL 32055
Parcel #: 02273-011
Acres: 1.16
Owner: Heims Norman K, Heims Ruth A
Subdivision: Spring Hollow
Zoning: RSF-2
Flood Zone: X
District: 1
Application #: 60503
Permit #: 000046785
Related Permit:
Submitted: Thursday, March 16, 2023
Issued: Monday, March 20, 2023
Expires: Thursday, March 30, 2023
Completed: Thursday, March 30, 2023
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 40
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL18355-R8
Product Manufacturer TAMKO Building Products LLC
Product Description ASTM D3462 asphalt shingles and hip and ridge shingles
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0283D
Review Notes
3/16/2023 Application pending.
3/16/2023 Application submitted by applicant.
3/17/2023 Final Review - Documents Required NEEDED * NORMAN AND RUTH HEIMS TO SIGN OWNER AND CONTRACTOR SIGNATURE PAGE
3/20/2023 Final Review - Documents Required NEEDED * NORMAN AND RUTH HEIMS TO SIGN OWNER AND CONTRACTOR SIGNATURE PAGE PLEASE SEND THE OWNER & CONTRACTOR SIGNATURE PAGE!!- YOU SENTTHE POA!!
3/20/2023 Final Review - Documents Required NEEDED * NORMAN AND RUTH HEIMS TO SIGN OWNER AND CONTRACTOR SIGNATURE PAGE PLEASE SEND THE OWNER & CONTRACTOR SIGNATURE PAGE!!- YOU SENTTHE POA!!
3/20/2023 Final Review - Reviewed
3/20/2023 Final Review - Payment Needed
3/20/2023 Permit Issued Permit #000046785 created and approved.
Contractors
Name/ Business License Title Role
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress In Progress, Old Roof Covering Removed, Dryer In, Ew Shiglesin Bundles On Roof Top Gary Pitzer 3/22/2023
Passed: Re-Roof - Final Anthony Aslan 3/30/2023