Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 102 SE IBIS WAY
LAKE CITY, FL 32025
Parcel #: 07592-665
Acres: 0.19
Owner: Rossiter Rose Ellen
Subdivision: Eastside Village Unit 6
Zoning: RMF-1
Flood Zone: X
District: 4
Application #: 60484
Permit #: 000046761
Related Permit:
Submitted: Wednesday, March 15, 2023
Issued: Thursday, March 16, 2023
Expires: Thursday, March 23, 2023
Completed: Thursday, March 23, 2023
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City provides water, sewer and natural gas to this area. The utility account is active for water service.
Job Details
Finished floor requirement
Fema map number 12023C0311D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) REPLACE WOOD AS NEEDED
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 33
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL18355-R8
Product Manufacturer TAMKO
Product Description HERITAGE
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
3/15/2023 Application pending.
3/15/2023 Application submitted by applicant.
3/15/2023 City of Lake City Utilities Notified City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
3/15/2023 Point Review - Processing
3/15/2023 Final Review - Payment Needed
3/16/2023 Permit Issued Permit #000046761 created and approved.
Contractors
Name/ Business License Title Role
Lewis G Walker
Lewis Walker Roofing Inc
Workers Comp & Employees Workers Comp Expired.
CCC1333551 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Old Roof Covering Removed And Partial Dryer In,no One At Site Gary Pitzer 3/21/2023
Passed: Re-Roof - Final Dem. Shingle Roof Covering, New Trim And Boots Gary Pitzer 3/23/2023