Permit Details

Permit Search

Permit

Roof Replacement or Repair

361 NE MARTIN LUTHER KING ST
LAKE CITY, FL 32055

Permit #
000046536
Application #
59060
Status Completed
  1. Submitted Feb 13, 2023
  2. Issued Feb 15, 2023
  3. Expires Sep 24, 2023
  4. Completed Mar 28, 2023

Property

Parcel #
10942-000
Owner
Horne Juanita, Horne Kimberly
Acres
0.24
Subdivision
—
Zoning
—
Flood zone
X
District
1

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0284D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Remove existing roof covering. Repair sheathing/decking.
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
1278
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
FL 14645.10
Product Manufacturer
Metal Sales Manufacturing Corp
Product Description
Min. 29 ga., 36" wide through fastened roof panel over min. 15/32” thick plywood deck.
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City
  4. Final Review - Documents Required
  5. Final Review - Payment Needed
  6. Permit Issued

Contractors

  • James Foster

    Patriot Response Group Llc

    License
    CCC1333614
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Mar 7, 2023

    Passed: Re-Roof - In Progress

    Old Roof Covering Off And Dryed In,starting On New Metal Roof, House Has Gable Vents

    Inspected by Gary Pitzer

  2. Mar 23, 2023

    Failed: Re-Roof - Final

    Need Flashing Sealed Next To House

    Inspected by Gary Pitzer

  3. Mar 28, 2023

    Passed: Re-Roof - Final

    Counter Flashing Installed

    Inspected by Troy Crews