Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Swimming Pool and Spa Permit

Address 136 SW STEWART LOOP
LAKE CITY, FL 32024
Parcel #: 03167-000
Acres: 1.82
Owner: Glenn Stephen C, Glenn Phyllis
Subdivision: Plantation Estates
Zoning: RSF-2
Flood Zone: X
District: 5
Application #: 58865
Permit #: 000046511
Related Permit:
Submitted: Monday, January 30, 2023
Issued: Monday, February 13, 2023
Expires: Thursday, August 3, 2023
Completed: Thursday, August 3, 2023
Status: Completed
Septic Release? Yes
Notes:

LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City provides water service to this area. This location is not connected to city utilities.
Job Details
Finished floor requirement
Fema map number 12023C0290D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Full re-roof, any rotten decking discovered will be replaced.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 3863
No. of Stories 2
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10124-R31
Other Roofing Product Type Not Listed Tri-Built Synthetic Roofing Underlayment FL22259-R3
Product Manufacturer GAF
Product Description Timberline HDZ Shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Second Roof Pitch (if applicable) 2:12 to 4:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
1/30/2023 Application pending.
1/30/2023 Application submitted by applicant.
1/30/2023 City of Lake City Utilities Notified
1/31/2023 Point Review - Reviewed
1/31/2023 Point Review - Printed-Online Application
1/31/2023 Plan Review - Reviewed
2/1/2023 Zoning Review - Reviewed
2/1/2023 Final Review - Documents Required
2/10/2023 Final Review - Reviewed
2/10/2023 Final Review - Payment Needed
2/13/2023 Permit Issued
Contractors
Name/ Business License Title Role
Susan Fraze
Aquatic Art Pools & Spas Llc
Workers Comp Expired.
CPC1457969 Comm. Pool/spa Contractor Contractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 2/13/2023
Passed: Engineering - Setbacks Gary Pitzer 3/8/2023
Passed: Swimming Pool - Pool Steel and Ground Steel All Bonded,4 Tails Out For Future Deck Gary Pitzer 3/8/2023
Passed: Swimming Pool - Pool Deck/Piping Pressure Steel And Bonded To Pool Side Walls, 30 Psi On Piping System During Inspection Gary Pitzer 5/19/2023
Failed: Swimming Pool - Pool Safety and Final Panel For The Pool Equipment Needs Bonded To Pool Bonding System, Pool Equipment Panel Requires Neutrals And Grounds To Be Separated And The Ground Need To Ground The Panel Box Gary Pitzer 8/1/2023
Swimming Pool-Pool Safety and Final Gary Pitzer 8/3/2023