Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 323 SW BROOKS CT
LAKE CITY, FL 32024
Parcel #: 03051-013
Acres: 20.58
Owner: Brooks Austin Chance
Subdivision:
Zoning: RR
Flood Zone: X
District: 3
Application #: 57204
Permit #: 000046492
Related Permit:
Submitted: Wednesday, November 23, 2022
Issued: Friday, February 10, 2023
Expires: Friday, December 15, 2023
Completed: Friday, December 15, 2023
Status: Completed
Septic Release? Yes
Notes:
MFE 12" ABOVE EXISTING ADJACENT GROUND
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 12" ABOVE EXISTING ADJACENT GROUND
Fema map number 12023C0290D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 2702
Total Area (Sqft) 3508
Building Height 29
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0942
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
11/18/2022 Application pending.
11/28/2022 Application submitted by applicant.
12/7/2022 Point Review - On Hold-Incomplete PLEASE CLICK EDIT AND COMPLETE ALL CELLS, THEN SUBMIT APPLICATION PLEASE REPLY TO ABOVE REQUEST. 12.7.22 - INCOMPLETE
12/14/2022 Point Review - Printed-Online Application NEEDED: *RESIDENTIAL CHECKLIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 * MICHAEL DAVIS TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *NOTARIZED AUTHORIZATION *ROOFING & ELECTRICAL SIGNED SUB VF *MCDONALD UPDATED LICENSE *HINES UPDATED LICENSE, LIABILITY, AND WORKERS COMP
12/14/2022 Point Review - Reviewed NEEDED: *RESIDENTIAL CHECKLIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 * MICHAEL DAVIS TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *NOTARIZED AUTHORIZATION *ROOFING & ELECTRICAL SIGNED SUB VF *MCDONALD UPDATED LICENSE *HINES UPDATED LICENSE, LIABILITY, AND WORKERS COMP
12/16/2022 Point Review - Reviewed NEEDED: *RESIDENTIAL CHECKLIST *NOTARIZED AUTHORIZATION *ROOFING & ELECTRICAL SIGNED SUB VF *MCDONALD UPDATED LICENSE *HINES UPDATED LICENSE, LIABILITY, AND WORKERS COMP
1/3/2023 Plan Review - Documents Required NEED: ** ENERGY FORM INTIALED BY SIGNER AND CHANGE SQFT.
1/9/2023 Plan Review - Documents Required NEED: ** ENERGY FORM INTIALED BY SIGNER AND CHANGE SQFT.
1/9/2023 Plan Review - Building Approved NEED:
1/9/2023 Plan Review - Electrical Approved NEED:
1/9/2023 Plan Review - Mechanical Approved NEED:
1/9/2023 Plan Review - Plumbing Approved NEED:
1/9/2023 Plan Review - Fuel/Gas Approved NEED:
1/9/2023 Plan Review - Reviewed NEED:
1/13/2023 Zoning Review - Reviewed NEED: THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
1/13/2023 Final Review - Reviewed NEED: THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
1/13/2023 Final Review - Contact the Building Dept NEED: CONTACT DAVID MOORE FOR PRIVATE ROAD DETAILS-- 386-758-2122 OR LINC @ 386-719-1456 THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
2/9/2023 Final Review - Reviewed
2/9/2023 Final Review - Payment Needed
2/10/2023 Permit Issued Permit #000046492 created and approved.
10/31/2023 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Phillip M Mcdonald
Phillip Mcdonald Plumbing Inc
County License & State License Expired.
CFC1428926 Cert. Plumbing Subcontractor
Mervin L Hines
Hines Electrical & Communication Inc
EC13003393 Electrical Contractor Subcontractor
Timothy D Shatto
Shatto Heating & Air, Inc.
CAC057875 A/c Class B Subcontractor
Michael Davis
Msd Construction & Contracting Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CBC1254008 Cert. Building Contractor
Inspections
Inspection Notes Performed By Date
Failed: Plumbing/Gas - 1st Underground Rough–In No Permit Posted No Noc No Compaction Test Matt Forsyth 2/28/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Items Addressed With Brittney Matt Forsyth 2/28/2023
Cancelled: Building - Footer Matt Forsyth 3/24/2023
Cancelled: Engineering - Setbacks Matt Forsyth 3/24/2023
Failed: Building - Monolithic Slab Slab Appears To Not Have Been Plate Compacted For Well Compacted Soil As Indicated On Plans Matt Forsyth 3/24/2023
Passed: Engineering - Setbacks Matt Forsyth 3/24/2023
Passed: Building - Monolithic Slab Items Addressed Matt Forsyth 3/29/2023
Passed: Engineering - Setbacks Matt Forsyth 3/29/2023
Passed: Building - Roof Decking Matt Forsyth 5/15/2023
Passed: Building - Wall Sheathing Matt Forsyth 5/15/2023
Passed: Building - Framing Missing 2 Gable Straps Will Check All For Next Inspection Matt Forsyth 6/1/2023
Failed: Electrical - 2nd Rough-In Not Complete No Outside Receptacles Island Not Matt Forsyth 6/16/2023
Passed: Mechanical - Rough In Matt Forsyth 6/16/2023
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 6/16/2023
Failed: Electrical - 2nd Rough-In No Outside Receptacles Roughed, Must Have One Front And Back. Also No Wire Roughed Out For Condensing Unit. Troy Crews 6/22/2023
Passed: Electrical - 2nd Rough-In Matt Forsyth 7/25/2023
Passed: Building - Insulation Matt Forsyth 8/18/2023
Passed: Electrical - Permanent Power Need Septic Matt Forsyth 10/16/2023
Release to power company Melissa Garber 10/23/2023
Septic Release Inspection Health Dept 10/23/2023
Failed: Building - Final Electrical Panel In House Needs To Be Properly Labeled Matt Forsyth 12/13/2023
Certificate-Release Certificate Item Was Addressed Matt Forsyth 12/14/2023
Passed: Building - Final Items Were Addressed Matt Forsyth 12/15/2023
Documents
File Name Date File Size
Lidar 57204 2023-01-13 11.40.07.166.pdf 2025.07.05 79.65kB
Termite Certificate Of Compliance.pdf 2025.07.05 84.92kB
Signed Mono Foundation 2023-03-16 13.49.53.879.pdf 2025.07.05 597.92kB
Product Approval Code Specifications Form 20221118 101805.pdf 2025.07.05 256.55kB
Brooks Eh 2022-12-13 09.37.15.433.pdf 2025.07.04 859.94kB
323 Sw Brooks Ct 2023-02-09 14.13.44.580.pdf 2025.07.04 217.45kB
Blower Test Pass.pdf 2025.07.04 920.39kB
Owner And Contractor Signature Page 20221118 101804.pdf 2025.07.04 398.48kB
Elevation Letter 1280 Sw Tompkins Street, Lake City, Fl 02-01-23.pdf 2025.07.04 1.01MB
Site Plan 20221118 101806.pdf 2025.07.04 133.93kB
Recorded Notice Of Commencement 20221219 204134.pdf 2025.07.04 475.48kB
Density Test Cal Tech 2023-03-16 13.48.57.567.pdf 2025.07.04 198.76kB
Property Appraiser Parcel Details Printed Page 20221118 102621.pdf 2025.07.04 875.09kB
Architectural Plans 20221118 101758.pdf 2025.07.04 624.05kB
Reviewed Architectural Plans 57204 2022-12-29 13.11.57.213.pdf 2025.07.04 631.21kB
Structural Engineering And Wind Load Calculations 20221122 090720.pdf 2025.07.04 3.35MB
Reviewed Structural Engineering And Wind Load Calculations 57204 2022-12-29 13.11.58.229.pdf 2025.07.04 3.35MB
Reviewed Truss Engineering 57204 2022-12-29 13.11.59.666.pdf 2025.06.26 16.35MB
Truss Engineering 20221118 101807.pdf 2023.12.23 27.10MB
Manual J Forms 20221122 090747.pdf 2023.12.23 1.11MB
Energy Code Forms 20221118 101802.pdf 2023.12.23 1.02MB
Residential Or Commercial Checklist 20221219 204135.pdf 2023.12.23 5.12MB
Certificate Of Occupancy 20231214.pdf 2023.12.23 68.97kB
Contractor Letter Of Authorization 20221219 134830.pdf 2023.12.23 92.11kB
Energy Code Forms 20230109 104010.pdf 2023.12.23 1.00MB
Certificate Of Occupancy 20231215.pdf 2023.12.15 68.97kB
Power Release-release To Power Company 20231023.pdf 2023.10.23 38.82kB
Original Permit 20230210.pdf 2023.02.10 45.92kB
Sub Vf Form.pdf 2022.12.19 91.91kB
Recorded Deed.pdf 2022.12.14 96.39kB
Epl Card.pdf 2022.11.18 308.48kB