Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 550 SW MANDIBA DR
LAKE CITY, FL 32024
Parcel #: 09280-118
Acres: 1.97
Owner: Roberts James Terrell, Roberts Melissa P
Subdivision: Oaks Of Lake City Phase 1
Zoning: PRRD
Flood Zone: X
District: 5
Application #: 58474
Permit #: 000046391
Related Permit: Culvert: 000046392
Submitted: Wednesday, December 21, 2022
Issued: Friday, January 27, 2023
Expires: Thursday, November 16, 2023
Completed: Thursday, November 16, 2023
Status: Completed
Septic Release? Yes
Notes:
MFE - 77' PER PLAT ELEVATION CONFIRMATION REC'D @ 77.4'
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 77'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0395C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2597
Total Area (Sqft) 4340
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 23-0058
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
12/20/2022 Application pending.
12/21/2022 Application submitted by applicant.
12/29/2022 Point Review - Printed-Online Application NEEDED: *911 ADDRESS *ENERGY CODE FORMS *MANUAL J FORMS *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
12/29/2022 Point Review - Reviewed NEEDED: *911 ADDRESS *ENERGY CODE FORMS *MANUAL J FORMS *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/5/2023 Plan Review - Corrections Needed NEEDED: **CLINT WORKERS COMP EXPIRED. **CORRECT SQFT ON CHECK LIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/5/2023 Plan Review - Building Approved NEEDED: **CLINT WORKERS COMP EXPIRED. **CORRECT SQFT ON CHECK LIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/5/2023 Plan Review - Electrical Approved NEEDED: **CLINT WORKERS COMP EXPIRED. **CORRECT SQFT ON CHECK LIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/5/2023 Plan Review - Mechanical Approved NEEDED: **CLINT WORKERS COMP EXPIRED. **CORRECT SQFT ON CHECK LIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/5/2023 Plan Review - Plumbing Approved NEEDED: **CLINT WORKERS COMP EXPIRED. **CORRECT SQFT ON CHECK LIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/5/2023 Plan Review - Fuel/Gas Approved NEEDED: **CLINT WORKERS COMP EXPIRED. **CORRECT SQFT ON CHECK LIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/5/2023 Plan Review - Reviewed NEEDED: **CLINT WORKERS COMP EXPIRED. **CORRECT SQFT ON CHECK LIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/9/2023 Plan Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/13/2023 Zoning Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/13/2023 Final Review - Documents Required NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/13/2023 Final Review - Documents Required NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDE NOC
1/27/2023 Final Review - Reviewed ***PRIOR TO INSPECTIONS*** RECORDED NOC
1/27/2023 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED NOC
1/27/2023 Permit Issued Permit #000046391 created and approved.
Contractors
Name/ Business License Title Role
Isaiah Cully
Ic Construction Llc
CBC1259655 Building Contractor Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Smith, Blake 1/30/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Under Slab Plumbing Drains Only, No Water Or Gas Gary Pitzer 2/16/2023
Passed: Engineering - Setbacks Gary Pitzer 2/22/2023
Passed: Building - Monolithic Slab Steel And Wire, Electric Bond Gary Pitzer 2/22/2023
Passed: Electrical - Temporary Service Gary Pitzer 2/24/2023
Release to power company Gary Pitzer 2/24/2023
Passed: Building - Roof Decking Gary Pitzer 4/6/2023
Passed: Building - Wall Sheathing Gary Pitzer 4/6/2023
Passed: Building - Framing Gary Pitzer 5/22/2023
Passed: Electrical - 2nd Rough-In Gary Pitzer 5/22/2023
Passed: Mechanical - Rough In Will Need Shut-valve Within 6 Ft Of Exterior Gas Fireplace Gary Pitzer 5/22/2023
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 5/22/2023
Passed: Building - Insulation Roof And Gables Foam, Walls Bats Gary Pitzer 6/8/2023
Septic Release Inspection Health Dept 8/11/2023
Passed: Electrical - Permanent Power Gary Pitzer 9/21/2023
Passed: Engineering - Final Driveway Beach, Garrett 9/22/2023
Passed: Electrical - Permanent Power Gary Pitzer 9/25/2023
Release to power company Gary Pitzer 9/25/2023
Passed: Building - Final Gary Pitzer 11/16/2023
Documents