Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Storage Building Permit
Address 449 SW ROLLING MEADOWS GLN
FORT WHITE, FL 32038
Parcel #: 03767-403
Acres: 5.00
Owner: Kutner David Warren, Kutner Deirdre Ann
Subdivision: Sedgefield Phase 4
Zoning: A-3
Flood Zone: X
District: 4
Application #: 57126
Permit #: 000046307
Related Permit:
Submitted: Friday, November 18, 2022
Issued: Friday, July 14, 2023
Expires: Tuesday, February 6, 2024
Completed: Tuesday, February 6, 2024
Status: Completed
Septic Release? No
Notes:
SHED IS AN OFF-GRADE FLOOR SYSTEM THAT WILL BE ON DRY STACK PIERS, NO PLUMBING, NEW SLAB **CHECK SIDE SETBACK IN FIELD NON-HABITABLE STRUCTURE
Job Details
Type of Structure Storage Building
Commercial or Residential? Residential
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setback Rear 10' (accessory)
Length 24
Width 24
Total Area (Sqft) 960
Building Height 16
Septic# (00-0000) or (X00-000) 22-0890
Dev Permit # F023-
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Storage
Occupancy Use Title non habitable storage
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Accessory Use
Finished floor requirement Non-Habitable Structure
Fema map number 12023C0390C
In floodway N
Review Notes
11/14/2022 Application pending.
11/27/2022 Application submitted by applicant.
12/15/2022 Point Review - Printed-Online Application NEEDED: *PRODUCT APPROVAL CODES *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *SIGNED ELECTRICAL SUB FORM-- IF INCLUDED, IF NOT, NOTATE NONE *SLAB, NO SLAB, EXISTING SLAB?
12/15/2022 Point Review - Reviewed NEEDED: *PRODUCT APPROVAL CODES *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *SIGNED ELECTRICAL SUB FORM-- IF INCLUDED, IF NOT, NOTATE NONE *SLAB, NO SLAB, EXISTING SLAB?
1/3/2023 Plan Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
1/6/2023 Zoning Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
1/6/2023 Final Review - Reviewed NEEDED:
1/6/2023 Final Review - Corrections Needed NEEDED: *WILL THERE BE ANY ELECTRICAL? *NEW SLAB, EXISTING SLAB, OR NO SLAB?
1/18/2023 Final Review - Reviewed
1/18/2023 Final Review - Payment Needed
1/19/2023 Permit Issued Permit #000046307 created and approved.
7/14/2023 Permit Reissued Permit reissued to reflect updated information.
Contractors

This is an owner builder project.

Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Building - Slab Gary Pitzer 2/27/2023
Cancelled: Building - Footer Melissa Garber 7/12/2023
Cancelled: Engineering - Setbacks Melissa Garber 7/12/2023
Building-Strapping Stapping Of Building Sub-floor To Slab Per Eng Report On File James Warner 7/13/2023
Passed: Engineering - Setbacks Gary Pitzer 7/13/2023
Passed: Building - Footer This Was Inspected On 2/27/23 /gp Gary Pitzer 7/13/2023
Building-Wall Sheathing Complete With Roof Sheeting Gary Pitzer 7/19/2023
Passed: Building - Roof Decking Roof Sheeting And Side Walls Nail Off Gary Pitzer 7/19/2023
Failed: Building - Framing 1. Needs All Spaces On Stairs And Balister To Be No Greater Than 4 Inches This Is To Include The Spaceing Under Open Stair Treads Also, 2. Stus And Strapes To Match Approved Plans, 3. Fasten Top Of Post By Stairs On Interior Gary Pitzer 9/13/2023
Passed: Electrical - 1st Underground Rough–In Gary Pitzer 10/18/2023
Passed: Building - Insulation Troy Crews 10/26/2023
Passed: Building - Final Non Habitable Storage Building Troy Crews 2/6/2024