Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 969 NW LAKE CITY AVE
LAKE CITY, FL 32055
Parcel #: 02330-000
Acres: 0.98
Owner: Ward Vicki
Subdivision:
Zoning: RSF/MH-2
Flood Zone: A
District: 3
Application #: 56540
Permit #: 000046251
Related Permit:
Submitted: Wednesday, September 21, 2022
Issued: Thursday, January 12, 2023
Expires: Friday, April 28, 2023
Completed: Friday, April 28, 2023
Status: Completed
Septic Release? na
Notes:
LAKE CITY UTLITY CUSTOMER SERVICE NOTES THE CITY OF LAKE CITY PROVIDES WATER, SEWER AND NATURAL GAS TO THIS AREA. PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 1700
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 2:12 to 4:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number 7006.1
Product Manufacturer IKO
Product Description CAMBRIDGE
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0280D
Review Notes
9/21/2022 Application pending.
9/21/2022 Application submitted by applicant.
9/21/2022 City of Lake City Utilities Notified City of Lake City Notified of Application within Utility Service Areas LC_GAS,.
9/21/2022 Final Review - Contact the Building Dept NEEDED: *LEWIS TO COMPLETE REGISTRATION-- CONTACT EMALEIGH @ 386-758-1008 FOR DETAILS
9/30/2022 Final Review - Corrections Needed NEEDED: *APPLICANT MUST BE CONTRACTOR OR AUTHORIZED AGENT *LEWIS UPDATED LIABILITY
10/12/2022 Final Review - Corrections Needed NEEDED: *APPLICANT MUST BE CONTRACTOR NAME, NOT COMPANY NAME OR AUTHORIZED AGENT
11/14/2022 Final Review - Payment Needed
12/13/2022 Final Review - Payment Needed
1/12/2023 Final Review - Documents Required **PLEASE PROVIDE WAIVER OR DOCUMENT SHOWING APPROVAL OF ARPA PROGRAM
1/12/2023 Permit Issued Permit #000046251 created and approved.
Contractors
Name/ Business License Title Role
Connie Lewis
Lewis Brothers Inc
County License & State License & Liability Insurance Expired.
CRC1326944 Cert. Residential Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - Final Troy Crews 4/27/2023