Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 10891 S US HIGHWAY 441
LAKE CITY, FL 32025
Parcel #: 09330-001
Acres:
Owner: Mosier Dennis Edward
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 57441
Permit #: 000046114
Related Permit:
Submitted: Thursday, December 15, 2022
Issued: Thursday, December 15, 2022
Expires: Monday, January 9, 2023
Completed: Monday, January 9, 2023
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Overlay with Metal
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) 10 sqaure of roof will be tear off and dry in with purlins. Replace wood as needed.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 34
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Metal roof over - Only 10 SQ will be torn off and dried in w/ Purlins
Type of New Roofing Product Metal
Florida Product Approval Number FL13838-2
Product Manufacturer Agrimetal
Product Description 26 GA Rib
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Sealed roof decking explanation for other option. Felt buster on 10 SQ dry in portion of roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0415C
Review Notes
12/15/2022 Application pending.
12/15/2022 Application submitted by applicant.
12/15/2022 Final Review - Payment Needed
12/15/2022 Permit Issued Permit #000046114 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Anthony Aslan 1/3/2023
Passed: Re-Roof - Final Anthony Aslan 1/9/2023