Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 351 SW REGINALD PL
LAKE CITY, FL 32024
Parcel #: 03271-001
Acres: 39.21
Owner: Poirrier James
Subdivision:
Zoning: A-3
Flood Zone: X
District: 5
Application #: 56719
Permit #: 000046094
Related Permit:
Submitted: Tuesday, October 18, 2022
Issued: Tuesday, December 13, 2022
Expires: Friday, July 21, 2023
Completed: Friday, July 21, 2023
Status: Completed
Septic Release? Yes
Notes:

Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0380C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Stories 1
Heated Area (Sqft) 3118
Total Area (Sqft) 3549
Building Height 23
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0777
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 400
Review Notes
10/7/2022 Application pending.
10/31/2022 Application submitted by applicant.
11/1/2022 Point Review - Printed-Online Application
11/9/2022 Plan Review - Building Approved
11/9/2022 Plan Review - Electrical Approved
11/9/2022 Plan Review - Mechanical Approved
11/9/2022 Plan Review - Plumbing Approved
11/9/2022 Plan Review - Fuel/Gas Approved
11/9/2022 Plan Review - Reviewed
11/10/2022 Zoning Review - Reviewed
11/10/2022 Final Review - Reviewed
11/14/2022 Final Review - Reviewed
11/14/2022 Final Review - Payment Needed
12/12/2022 Final Review - Payment Needed
12/13/2022 Permit Issued
5/16/2023 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Bryan Zecher
Bryan Zecher Homes Inc
CBC1257343 Building Contractor Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Robert Ogles
Ogles Roofing & Construction Llc
CCC1328699 Cert Roofing Subcontractor
Donald R Hollingsworth
Holly Electric Inc
EC13005429 Electrical Subcontractor
Anthony R Franks
Lane Heating & Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Failed: Building - Footer Inspectors Need Access To The Project Matt Forsyth 12/22/2022
Failed: Engineering - Setbacks Matt Forsyth 12/22/2022
Passed: Building - Footer Matt Forsyth 12/27/2022
Passed: Engineering - Setbacks Matt Forsyth 12/27/2022
Cancelled: Building - Footer Matt Forsyth 12/28/2022
Cancelled: Engineering - Setbacks Matt Forsyth 12/28/2022
Passed: Electrical - Temporary Service Matt Forsyth 12/30/2022
Release to power company Matt Forsyth 12/30/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Test Was Taken On The Lowest Fixture Served Matt Forsyth 2/1/2023
Passed: Building - Slab Troy Crews 2/7/2023
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 2/28/2023
Passed: Building - Framing Matt Forsyth 2/28/2023
Passed: Building - Roof Decking Matt Forsyth 2/28/2023
Passed: Building - Strapping Matt Forsyth 2/28/2023
Passed: Building - Wall Sheathing Matt Forsyth 2/28/2023
Passed: Electrical - 2nd Rough-In Matt Forsyth 3/27/2023
Passed: Mechanical - Rough In Matt Forsyth 3/27/2023
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 3/27/2023
Passed: Plumbing/Gas - Tub Set/Shower Pan Matt Forsyth 3/27/2023
Passed: Building - Insulation Matt Forsyth 4/3/2023
Passed: Building - Lath/Stucco Fasteners And Accent Band Matt Forsyth 4/4/2023
Septic Release Inspection Health Dept 5/16/2023
Failed: Electrical - Permanent Power Service Entrance Not Run,also Panel Inside Not Complete Matt Forsyth 5/22/2023
Passed: Electrical - Permanent Power Matt Forsyth 5/25/2023
Release to power company Matt Forsyth 5/25/2023
Failed: Building - Final Final Grade Around Home Not Complete. Step Missing At Back Door. Proof Of Makeup Air . Water To All Fixtures. Matt Forsyth 7/18/2023
Passed: Building - Final Items Addressed Matt Forsyth 7/21/2023