Permit Details

Permit Search

Permit

New Residential Construction

620 NW LAKE VALLEY TER
LAKE CITY , FL 32055

Permit #
000046031
Application #
56758
Status Completed
  1. Submitted Oct 14, 2022
  2. Issued Dec 5, 2022
  3. Expires Apr 13, 2024
  4. Completed Oct 16, 2023

Property

Parcel #
02269-133
Owner
Hosford Thomas E Iii, Hosford Bridget E
Acres
0.64
Subdivision
Lake Valley In Woodborough
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0280D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
2
Heated Area (Sqft)
2597
Total Area (Sqft)
3975
Building Height
23
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0903
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Point Review - Reviewed
  5. Plan Review - Corrections Needed
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Documents Required
  9. Plan Review - Documents Required
  10. Plan Review - Documents Required
  11. Plan Review - Documents Required
  12. Plan Review - Building Approved
  13. Plan Review - Electrical Approved
  14. Plan Review - Mechanical Approved
  15. Plan Review - Plumbing Approved
  16. Plan Review - Fuel/Gas Approved
  17. Plan Review - Reviewed
  18. Zoning Review - Reviewed
  19. Final Review - Reviewed
  20. Final Review - Payment Needed
  21. Permit Issued
  22. Final Review - Payment Needed

Contractors

  • Isaiah Cully

    Ic Construction Llc

    License
    CBC1259655
    Title
    Building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Subcontractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor

Inspections

  1. Dec 7, 2022

    Passed: Building - Footer

    Need Toilet Onsite Before Further Inspections.

    Inspected by Troy Crews

  2. Dec 7, 2022

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Jan 20, 2023

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  4. Jan 26, 2023

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Mar 24, 2023

    Failed: Building - Roof Decking

    Nailing Of Roof Still In Progress, Lots Of Nails That Have Missed Roof Trusses (shiners)

    Inspected by Gary Pitzer

  6. Mar 24, 2023

    Failed: Building - Wall Sheathing

    Nails Missing Outer Studs (shiners), All Nails Mixing Framing In Roof And Walls Need Removed

    Inspected by Gary Pitzer

  7. Mar 29, 2023

    Passed: Building - Wall Sheathing

    Inspected by Gary Pitzer

  8. Mar 29, 2023

    Passed: Building - Roof Decking

    Inspected by Gary Pitzer

  9. May 19, 2023

    Failed: Plumbing/Gas - 2nd Rough-In

    Install Pro Plate That Is On Floor, Move Two Water Pipes Away From Edge Of Studs, Two Drains Out Of Walls?

    Inspected by Gary Pitzer

  10. May 19, 2023

    Failed: Mechanical - Rough In

    Fireplace Chimney Incomplete, Vents Mashed(main Entry And Second Floor Bath And Bedroom), Also Before Finalexterior Linesets Will Need Proer Insulation

    Inspected by Gary Pitzer

  11. May 19, 2023

    Failed: Electrical - 2nd Rough-In

    Missing Pro Plates,need Uf Cable Under Slab In Kitchen

    Inspected by Gary Pitzer

  12. May 19, 2023

    Failed: Building - Framing

    Missing Nails In Hangersnear Stairs, Need Hangers On Floor Trusses In Closet,anchor Bolst In Several Locations

    Inspected by Gary Pitzer

  13. May 25, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Gary Pitzer

  14. May 25, 2023

    Failed: Mechanical - Rough In

    Items From Previous Inspection Still Needs Attention

    Inspected by Gary Pitzer

  15. May 25, 2023

    Failed: Plumbing/Gas - 2nd Rough-In

    Items From Previous Inspection Still Required Attention

    Inspected by Gary Pitzer

  16. May 25, 2023

    Failed: Building - Framing

    Pipe In Master Closet Needs Some Framing To Complete , This Has Not Changed Since Last Inspection

    Inspected by Gary Pitzer

  17. Jun 16, 2023

    Passed: Mechanical - Rough In

    Exterior Line Set Must Have Proper Insulation On Final

    Inspected by Troy Crews

  18. Jun 16, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Wall Furred Out Nail Plates Installed

    Inspected by Troy Crews

  19. Jun 16, 2023

    Passed: Building - Framing

    Pipes In Closet Corrdcted.

    Inspected by Troy Crews

  20. Jun 20, 2023

    Failed: Building - Insulation

    Has Not Passed Framing Do Not Insulate

    Inspected by Troy Crews

  21. Jun 20, 2023

    Building-Framing

    Framing Defects Corrected

    Inspected by Gary Pitzer

  22. Jun 20, 2023

    Building-Insulation

    Inspected by Gary Pitzer

  23. Jul 19, 2023

    Septic Release Inspection

    Inspected by Health Dept

  24. Aug 18, 2023

    Passed: Electrical - Permanent Power

    Need Final Drive

    Inspected by Gary Pitzer

  25. Aug 24, 2023

    Passed: Electrical - Permanent Power

    Road Has Been Repaired

    Inspected by Troy Crews

  26. Aug 24, 2023

    Release to power company

    Inspected by Troy Crews

  27. Oct 12, 2023

    Failed: Building - Final

    1. Arc-fault Circuit Breakers Required On All Kitchen Counter Circuits, 2. Range Outlets Requires A Cover, 3. All Bathrooms Require Gfci Protection, 4. All Fans Should Operate On Rear Porch, 5. Handrail Required For Second Set Of Steps, 6. Hearth At Fireplace, 7. Engineer Letter For House Finish Floor And Road Elevation

    Inspected by Gary Pitzer

  28. Oct 13, 2023

    Failed: Building - Final

    Hearth Not Complete

    Inspected by Gary Pitzer

  29. Oct 16, 2023

    Passed: Building - Final

    Inspected by Gary Pitzer

  30. Requested

    Electrical - Permanent Power

    Awaiting inspection