Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 5979 SW STATE ROAD 247
LAKE CITY, FL 32024
Parcel #: 03236-117
Acres: 2.00
Owner: Cassidy Timothy P Sr,
Subdivision: Kelliche Estates
Zoning: RR
Flood Zone: X
District: 2
Application #: 57301
Permit #: 000046017
Related Permit:
Submitted: Thursday, December 1, 2022
Issued: Thursday, December 1, 2022
Expires: Friday, December 9, 2022
Completed: Friday, December 9, 2022
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Overlay with Metal
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 32
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Doing metal overlay
Type of New Roofing Product Metal
Florida Product Approval Number # 17992.1 R3
Product Manufacturer CAPITAL METAL SUPPLY, INC.
Product Description Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16” OSB
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0380C
Review Notes
12/1/2022 Application pending.
12/1/2022 Application submitted by applicant.
12/1/2022 Point Review - Processing
12/1/2022 Final Review - Payment Needed
12/1/2022 Permit Issued Permit #000046017 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Matt Forsyth 12/6/2022
Passed: Re-Roof - Final Troy Crews 12/9/2022