Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 370 SW MAGNOLIA LN
FORT WHITE, FL 32038
Parcel #: 10058-330
Acres: 2.05
Owner: Plasencia Nelson M, Plasencia Linda C
Subdivision: Santa Fe River Plantations
Zoning: A-3
Flood Zone: X
District: 2
Application #: 57065
Permit #: 000045875
Related Permit:
Submitted: Tuesday, November 8, 2022
Issued: Tuesday, November 8, 2022
Expires: Wednesday, December 14, 2022
Completed: Wednesday, December 14, 2022
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Remove existing shingles and replace with new shingles.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2663
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10124-R31
Product Manufacturer GAF
Product Description Architectural Shingles
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0532C
Review Notes
11/7/2022 Application pending.
11/8/2022 Application submitted by applicant.
11/8/2022 Final Review - Payment Needed
11/8/2022 Permit Issued Permit #000045875 created and approved.
Contractors
Name/ Business License Title Role
Donald Burnsed
True Force Roofing
CCC1333814 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Anthony Aslan 12/9/2022
Passed: Re-Roof - Final Anthony Aslan 12/14/2022