Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 231 SE ROSEWOOD CIR
LAKE CITY, FL 32025
Parcel #: 07592-109
Acres: 0.19
Owner: Sammons Julia Sullivan Dowling,
Subdivision: Eastside Village Unit 2
Zoning: RMF-1
Flood Zone: X
District: 4
Application #: 57000
Permit #: 000045831
Related Permit:
Submitted: Tuesday, November 1, 2022
Issued: Wednesday, November 2, 2022
Expires: Friday, January 13, 2023
Completed: Friday, January 13, 2023
Status: Completed
Septic Release? na
Notes:

LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City provides water, sewer and natural gas to this location. The utility account is active.
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 24
No. of Stories 1
Ventilation: Off-ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Second Roof Pitch (if applicable) Less than 2:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number 10124.1
Product Manufacturer GAF
Product Description ASPHALT ROOF SHINGLES
Other Roofing Product Type Not Listed GARDNER ASPHALT, APOC UNDERLAYMENT, # 21652.1, 3 sq. JM TPO ROOF SYSTEM # 11475.1
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0311D
Review Notes
11/1/2022 Application pending.
11/1/2022 Application submitted by applicant.
11/1/2022 City of Lake City Utilities Notified City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
11/1/2022 Point Review - Processing
11/1/2022 Final Review - Payment Needed
11/2/2022 Permit Issued Permit #000045831 created and approved.
Contractors
Name/ Business License Title Role
John G Oneal
Oneal Roofing Company
CCC1329495 Roofing Contractor Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Inprogress, Rubber Roof Gary Pitzer 12/29/2022
Passed: Re-Roof - Final Ew Black Roof Shingles With New Boots, Roof Vents And Ridge Vent New Edging Metal Gary Pitzer 1/13/2023