Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 336 NW MCGLEW LN
LAKE CITY, FL 32055
Parcel #: 02365-009
Acres: 11.60
Owner: Strickland Earl, Strickland Lynda P
Subdivision:
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 56619
Permit #: 000045571
Related Permit:
Submitted: Tuesday, September 27, 2022
Issued: Tuesday, September 27, 2022
Expires: Wednesday, November 23, 2022
Completed: Wednesday, November 23, 2022
Status: Completed
Septic Release? na
Notes:
PICS REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replace wood as needed
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 43
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Metal
Florida Product Approval Number FL17992.R2
Product Manufacturer Capital
Product Description 26 GA Rib
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Sealed roof decking explanation for other option. Metal roof-over with purlins no underlayment needed.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0280D
Review Notes
9/26/2022 Application pending.
9/27/2022 Application submitted by applicant.
9/27/2022 Point Review - Processing
9/27/2022 Final Review - Payment Needed
9/27/2022 Permit Issued Permit #000045571 created and approved.
Contractors
Name/ Business License Title Role
Lewis G Walker
Lewis Walker Roofing Inc
CCC1333551 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Matt Forsyth 11/17/2022
Passed: Re-Roof - Final Troy Crews 11/23/2022