Permit Details

Permit Search

Permit

New Residential Construction

472 SW MANNING PL
LAKE CITY, FL 32024

Permit #
000045405
Application #
54671
Status Completed
  1. Submitted Jun 15, 2022
  2. Issued Sep 9, 2022
  3. Expires Jan 10, 2024
  4. Completed Jul 14, 2023

Property

Parcel #
09630-009
Owner
Benner Paula,
Acres
13.52
Subdivision
Heatherwood
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0505C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Stories
1
Heated Area (Sqft)
1031
Total Area (Sqft)
1584
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0690
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Final Review - Corrections Needed
  3. Final Review - Contact the Building Dept
  4. Final Review - Status Cleared
  5. Point Review - Printed-Online Application
  6. Point Review - Reviewed
  7. Plan Review - Documents Required
  8. Plan Review - Corrections Needed
  9. Plan Review - Building Approved
  10. Plan Review - Electrical Approved
  11. Plan Review - Mechanical Approved
  12. Plan Review - Plumbing Approved
  13. Plan Review - Reviewed
  14. Zoning Review - Reviewed
  15. Final Review - Reviewed
  16. Final Review - Reviewed
  17. Final Review - Documents Required
  18. Final Review - Documents Required
  19. Final Review - Reviewed
  20. Final Review - Payment Needed
  21. Permit Issued
  22. Final Review - Payment Needed

Contractors

  • Robert Clark

    R&m Construction & Development Llc

    License
    CBC1256838
    Title
    Certified Building
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Paul K Coleman

    Colemans Plumbing Inc.

    License
    CFC1425624
    Title
    Certified Plumbing
    Role
    Subcontractor

    County License & State License & Employees Workers Comp Expired.

  • William P Duffield

    Duffield Home Improvement

    License
    CCC1325785
    Title
    Roofing Contractor
    Role
    Subcontractor
  • David D Clark

    Clark Electric Inc

    License
    EC13003577
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Employees Workers Comp Expired.

  • Robert M Bounds

    Bounds Heating & Air Inc

    License
    CAC057642
    Title
    Class A A/c
    Role
    Subcontractor

Inspections

  1. Sep 13, 2022

    Septic Release Inspection

    Inspected by Health Dept

  2. Sep 23, 2022

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  3. Sep 23, 2022

    Passed: Building - Footer

    Inspected by Anthony Aslan

  4. Nov 3, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  5. Nov 17, 2022

    Passed: Building - Slab

    Inspected by Anthony Aslan

  6. Dec 15, 2022

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  7. Dec 15, 2022

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  8. Feb 22, 2023

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  9. Mar 9, 2023

    Cancelled: Mechanical - Rough In

    Inspected by Anthony Aslan

  10. Mar 9, 2023

    Passed: Building - Framing

    Inspected by Anthony Aslan

  11. Mar 9, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  12. Mar 9, 2023

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  13. Mar 9, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  14. Mar 23, 2023

    Passed: Building - Insulation

    Front & Back Door Not Installed

    Inspected by Anthony Aslan

  15. Jun 9, 2023

    Passed: Electrical - Permanent Power

    Inspected by Gary Pitzer

  16. Jun 9, 2023

    Release to power company

    Inspected by Gary Pitzer

  17. Jul 14, 2023

    Passed: Building - Final

    No Gas Appliance In Fireplace, Valve On End Of Pipe

    Inspected by Gary Pitzer

Documents