Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 271 SE POLK LN
LAKE CITY, FL 32025
Parcel #: 08360-015
Acres: 0.32
Owner: Jernigan Alvin D Jr
Subdivision: Village Wood Unit 1
Zoning: RSF-2
Flood Zone: X
District: 5
Application #: 56302
Permit #: 000045403
Related Permit:
Submitted: Wednesday, August 31, 2022
Issued: Friday, September 9, 2022
Expires: Thursday, July 6, 2023
Completed: Thursday, July 6, 2023
Status: Completed
Septic Release? na
Notes:
LAKE CITY UTLITY CUSTOMER SERVICE NOTES THE CITY OF LAKE CITY PROVIDES WATER IN THIS AREA. THE UTILITY ACCOUNT IS ACTIVE. CANCELLATION REQUEST REC'D 7/6/2023-- MG
Job Details
Finished floor requirement
Fema map number 12023C0313D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2829
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL-18355
Product Manufacturer TAMKO
Product Description HERITAGE SHINGLE
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Review Notes
8/31/2022 Application pending.
8/31/2022 City of Lake City Utilities Notified City of Lake City Notified of Application within Utility Service Areas LC_WATER,.
8/31/2022 Final Review - Corrections Needed NEEDED * UPDATED STATE LICENSE FOR CALEB CROSS
9/9/2022 Final Review - Payment Needed NEEDED * UPDATED STATE LICENSE FOR CALEB CROSS
9/9/2022 Permit Issued Permit #000045403 created and approved.
7/6/2023 Application Voided This application was voided and not refunded
Contractors
Name/ Business License Title Role
Caleb Cross
Florida Premier Roofing Llc
CCC1332129 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Documents
File Name Date File Size