Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 412 NW LEVI GLN
LAKE CITY, FL 32055
Parcel #: 02032-213
Acres: 5.05
Owner: Miller Chandra Linise
Subdivision: Hills Of Huntsville Phase 2
Zoning: A-3
Flood Zone: X
District: 3
Application #: 53942
Permit #: 000045348
Related Permit:
Submitted: Tuesday, August 2, 2022
Issued: Wednesday, August 31, 2022
Expires: Thursday, August 8, 2024
Completed: Thursday, August 8, 2024
Status: Completed
Septic Release? Yes
Notes:
MFE: 110' PER PLAT ENGINEER LETTER FOR FINISHED FLOOR IN AGREEMENT WITH SURVEYOR CONFIRMATION.
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1999
Total Area (Sqft) 3030
Stories 1
Building Height 23
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 22-0673
Service Amps 200
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Engineers Elevation Letter
Finished floor requirement 108.09'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0280D
In floodway N
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
3/14/2022 Application pending.
8/2/2022 Point Review - Processing ROGER: PLEASE FINISH UPLOADING THE FOLLOWING ITEMS: BLUEPRINTS WIIND LOAD ENERGY CALCS MANUAL J SUB-VF RESIDENTIAL CHECKLIST & TRUSS REPORT
8/11/2022 Point Review - Printed-Online Application PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED IN NEEDED: TRUSS REPORT EH APPROVED PAPERWORK - 386.758.1058
8/31/2022 Plan Review - Plumbing Approved PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED I
8/31/2022 Plan Review - Mechanical Approved PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED I
8/31/2022 Plan Review - Electrical Approved PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED I
8/31/2022 Plan Review - Building Approved PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED I
8/31/2022 Plan Review - Reviewed PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED I
8/31/2022 Zoning Review - Reviewed PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED I
8/31/2022 Final Review - Reviewed PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED I
8/31/2022 Final Review - Payment Needed PLANS REVIEWER: HARD COPIES BLUEPRINTS RECEIVED W/SEALS & SCANNED I
8/31/2022 Permit Issued Permit #000045348 created and approved.
1/24/2024 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Matthew H Burns
Burns Electrical Services Inc
EC13006531 Electrical Contractor Subcontractor
Roger Whiddon
Lake City Plumbing Inc
CFC1428686 Cert Plumbing Subcontractor
Roger Whiddon
Whiddon Construction Co. Inc
Liability Insurance & Employees Workers Comp Expired.
CRC1328025 Residential Contractor Contractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Receptacles Used Will Be Ground Fault Protected Matt Forsyth 10/4/2022
Release to power company Matt Forsyth 10/4/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Compaction Test Needed Matt Forsyth 10/4/2022
Passed: Building - Slab Fiber Mesh Concrete Being Used Matt Forsyth 10/11/2022
Release to power company Changed From Fpl To Sve Melissa Garber 10/18/2022
Cancelled: Building - Roof Decking Matt Forsyth 11/2/2022
Failed: Building - Wall Sheathing All Nails Missing Framing Members Must Be Removed And Re Nailed All 8 Foot Blocking On Wall Sheathing Must Be Installed The Perimeter Wall Was Missing Several Nails Needs To Be Gone Back Over Matt Forsyth 11/2/2022
Passed: Building - Wall Sheathing Matt Forsyth 11/4/2022
Failed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 3/1/2023
Passed: Building - Roof Decking Matt Forsyth 3/1/2023
Failed: Building - Framing Call Matt Matt Forsyth 3/1/2023
Cancelled: Building - Wall Sheathing Matt Forsyth 4/11/2023
Passed: Building - Framing Matt Forsyth 4/11/2023
Failed: Electrical - 2nd Rough-In Pigtails Need To Be Inside Box Matt Forsyth 4/11/2023
Failed: Mechanical - Rough In Black Tape Not Listed For Duct Matt Forsyth 4/11/2023
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 4/11/2023
Passed: Electrical - 2nd Rough-In Matt Forsyth 4/13/2023
Passed: Mechanical - Rough In Matt Forsyth 4/13/2023
Cancelled: Building - Insulation Matt Forsyth 4/20/2023
Passed: Building - Insulation Matt Forsyth 4/25/2023
Passed: Engineering - Spot Check Need Conduit Run Underground For Permanent Power Matt Forsyth 11/9/2023
Passed: Electrical - Permanent Power Garage Doors Were Being Installed Need Septic Release Matt Forsyth 1/25/2024
Release to power company Melissa Garber 2/21/2024
Septic Release Inspection Health Dept 2/21/2024
Passed: Engineering - Spot Check Needed Us To Look To See If Anything Would Hold Up Co. Several Items Remain Incomplete, No Testing On Electric Done. Few Lights Missing. No Lifemsafty Tested Or Given, . No Inspection Completed On This Trip. Gary Pitzer 7/18/2024
Rescheduled 8/7/2024:Building - Final Troy Crews 8/6/2024
Failed: Building - Final Permit Holders Responsibility To Have Access To Inspection Matt Forsyth 8/7/2024
Passed: Building - Final Matt Forsyth 8/8/2024
Documents
File Name Date File Size
Certificate Of Occupancy 20240808.pdf 2024.08.08 69.04kB
Blower Door Test Results 20240802 092759.pdf 2024.08.02 1.32MB
Pre-slab Elevation Certification 20240722 112639.pdf 2024.07.22 429.17kB
Termite Treatment_initial 20240722 110819.pdf 2024.07.22 602.98kB
Termite Certificate_final 20240722 110450.pdf 2024.07.22 221.19kB
Power Release-release To Power Company 20240221.pdf 2024.02.21 39.06kB
Updated Electrical Sub Vf 53942 2022-08-31 11.33.49.790.pdf 2023.12.23 1.04MB
Truss Engineering 20220822 093632.pdf 2023.12.23 2.63MB
Subcontractor Form 20220809 103921.pdf 2023.12.23 631.02kB
Engineer Letter For Mfe.pdf 2023.12.23 1.86MB
Power Release-release To Power Company 20221018.pdf 2023.12.23 38.92kB
Property Appraiser Parcel Details Printed Page 20220802 155742.pdf 2023.12.23 1,018.19kB
Termite Certificate.pdf 2023.12.23 602.98kB
Manual J Forms 20220809 100922.pdf 2023.12.23 147.99kB
Surveyor Letter Giving The Finished Floor Elevation 45348.pdf 2023.12.23 432.27kB
911 Address Form 20220802 155741.pdf 2023.12.23 247.65kB
Recorded Notice Of Commencement 20220802 155742.pdf 2023.12.23 51.90kB
Residential Or Commercial Checklist 20220808 114329.pdf 2023.12.23 885.41kB
Approved Truss Plans 53942 2022-08-31 07.45.30.532.pdf 2023.12.23 2.74MB
Recorded Deed 20220531 102118.pdf 2023.12.23 67.24kB
Architectural Plans 20220808 120624.pdf 2023.12.23 600.19kB
Power Release-electrical-temporary Service 20221004.pdf 2023.12.23 38.91kB
Owner And Contractor Signature Page 20220531 102117.pdf 2023.12.23 2.52MB
Compaction Test.pdf 2023.12.23 201.99kB
Win_20221011_09_46_48_pro 2022-10-11 09.47.10.237.jpg 2023.12.23 271.69kB
Site Plan 20220802 155743.pdf 2023.12.23 71.03kB
Lidar 53942 2022-08-31 10.13.52.213.pdf 2023.12.23 119.45kB
45348 Plans.pdf 2023.12.23 25.37MB
Energy Code Forms 20220809 100921.pdf 2023.12.23 624.78kB
Septic Approval Paperwork 20220822 115444.pdf 2023.12.23 1.06MB
Product Approval Code Specifications Form 20220802 155741.pdf 2023.12.23 252.97kB
Original Permit 20220831.pdf 2023.12.23 46.10kB
Structural Engineering And Wind Load Calculations 20220808 120624.pdf 2023.12.23 386.24kB