Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 528 SW UPSTAGE GLN
LAKE CITY, FL 32024
Parcel #: 09280-140
Acres: 4.67
Owner: Judson Robert P, Judson Kimberly M
Subdivision: Oaks Of Lake City Phase 1
Zoning: PRRD
Flood Zone: X
District: 5
Application #: 55375
Permit #: 000045339
Related Permit: Culvert: 000045340
Submitted: Thursday, July 7, 2022
Issued: Tuesday, August 30, 2022
Expires: Friday, April 28, 2023
Completed: Friday, April 28, 2023
Status: Completed
Septic Release? Yes
Notes:
MFE: 77' PER PLAT ELEVATION CONFIRMATION REC'D @ 101.33'
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2688
Total Area (Sqft) 4170
Stories 1
Building Height 25
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Septic# (00-0000) or (X00-000) 22-0536
Service Amps 200
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Subdivision Plat
Finished floor requirement 77'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0395C
In floodway N
Sealed roof decking options. (Must select one option per FBC 2020 7th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Review Notes
6/27/2022 Application pending.
8/15/2022 Point Review - Printed-Online Application
8/24/2022 Plan Review - Documents Required NEEDED * UPLOAD TRUSS IS STRUCTURAL ENGINEERING, NEED TRUSS ENGINEERING
8/25/2022 Plan Review - Building Approved
8/25/2022 Plan Review - Electrical Approved
8/25/2022 Plan Review - Mechanical Approved
8/25/2022 Plan Review - Plumbing Approved
8/25/2022 Plan Review - Fuel/Gas Approved
8/25/2022 Plan Review - Reviewed
8/29/2022 Zoning Review - Reviewed
8/30/2022 Final Review - Reviewed
8/30/2022 Final Review - Reviewed
8/30/2022 Final Review - Payment Needed
8/30/2022 Permit Issued Permit #000045339 created and approved.
3/16/2023 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Bryan Zecher
Bryan Zecher Homes Inc
CBC1257343 Building Contractor Subcontractor
Anthony R Franks
Lane Heating & Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Donald R Hollingsworth
Holly Electric Inc
EC13005429 Electrical Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Robert Ogles
Ogles Roofing & Construction Llc
CCC1328699 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Smith, Blake 9/2/2022
Passed: Building - Footer Troy Crews 9/12/2022
Passed: Engineering - Setbacks Troy Crews 9/12/2022
Passed: Electrical - Temporary Service Troy Crews 9/26/2022
Release to power company Troy Crews 9/26/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 10/11/2022
Passed: Building - Slab Troy Crews 10/14/2022
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 11/22/2022
Passed: Building - Roof Decking Anthony Aslan 11/22/2022
Passed: Building - Framing Troy Crews 11/30/2022
Passed: Mechanical - Rough In Adjust Chimney Pipe For Clearance To Osb Troy Crews 12/22/2022
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 12/22/2022
Passed: Electrical - 2nd Rough-In Troy Crews 12/22/2022
Passed: Building - Insulation Troy Crews 1/10/2023
Septic Release Inspection Health Dept 3/14/2023
Passed: Engineering - Final Driveway Smith, Blake 3/17/2023
Passed: Electrical - Permanent Power Troy Crews 3/17/2023
Release to power company Troy Crews 3/17/2023
Passed: Building - Final Gas Appliances Not On, Have Final Start Up Checked By Gas Supplier. Troy Crews 4/28/2023
Documents
File Name Date File Size
Septic Approval Paperwork 20220707 140938.pdf 2023.12.24 1.21MB
45339 Blower Door 2023-05-01 07.09.01.693.jpg 2023.12.24 3.35MB
Product Approval Code Specifications Form 20220706 103731.pdf 2023.12.24 539.92kB
Termite Certificate_final 20230425 145746.pdf 2023.12.24 34.67kB
Recorded Notice Of Commencement 20220713 165510.pdf 2023.12.24 375.85kB
Residential Or Commercial Checklist 20220707 140800.pdf 2023.12.24 2.59MB
Reviewed Truss Engineering 55375 2022-08-25 12.49.06.365.pdf 2023.12.24 4.23MB
Architectural Plans 20220701 131005.pdf 2023.12.24 3.78MB
Original Permit 20220830.pdf 2023.12.24 135.60kB
Termite Treatment_initial 20230425 145746.pdf 2023.12.24 34.67kB
Certificate Of Occupancy 20230428.pdf 2023.12.24 54.53kB
Subcontractor Form 20220701 130749.pdf 2023.12.24 546.42kB
Blower Door Test Results 20230425 145745.pdf 2023.12.24 898.44kB
Property Appraiser Parcel Details Printed Page 20220701 130740.pdf 2023.12.24 339.48kB
Win_20221014_16_12_29_pro 2022-10-14 16.15.49.380.jpg 2023.12.24 94.66kB
Owner And Contractor Signature Page 20220706 103728.pdf 2023.12.24 633.76kB
Energy Code Forms 20220701 131007.pdf 2023.12.24 799.53kB
Site Plan 20220701 130744.pdf 2023.12.24 232.91kB
Reviewed Architectural Plans 55375 2022-08-24 09.54.01.216.pdf 2023.12.24 3.47MB
Power Release-electrical-permanent Power 20230317.pdf 2023.12.24 39.06kB
Truss Engineering 20220824 100450.pdf 2023.12.24 3.94MB
911 Address Form 20220701 130736.pdf 2023.12.24 175.32kB
Reviewed Structural Engineering And Wind Load Calculations 55375 2022-08-24 09.53.59.779.pdf 2023.12.24 4.73MB
Surveyor Letter Giving The Finished Floor Elevation 20221101 145619.pdf 2023.12.24 204.37kB
Structural Engineering And Wind Load Calculations 20220701 131009.pdf 2023.12.24 4.70MB
Truss Engineering 20220701 131057.pdf 2023.12.24 4.70MB
Recorded Deed 20220627 110840.pdf 2023.12.24 64.68kB
Power Release-electrical-temporary Service 20220926.pdf 2023.12.24 38.92kB
Manual J Forms 20220701 131008.pdf 2023.12.24 75.50kB
Lidar 55375 2022-08-29 12.28.33.376.pdf 2023.12.24 82.32kB