| Finished floor requirement |
|
| Fema map number |
12023C0480C |
| Type Roofing Job |
Replacement - Tear off Existing and Replace |
| Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
Remove single layer of shingles and felt to expose decking for examination,Remove existing off ridge vents and deck over openings
Reuse & reseal existing metal chimney flashings (when possible,Provide & install new factory painted galvanized eaves drip, Provide & install two layers of OC ProArmor synthetic underlayment, Provide & install OC WeatherLock self-adhered leak barrier in valleys,Provide & install 26g galvanized coil metal in valleys,Provide & install OC Starter Roll at eaves,Provide & install OC Duration TruDefinition architectural shingles, Provide & install OC Ventsure Heat & Moisture Ridge Vent, Provide & install OC ProEdge hip and ridge cap, Provide & install new Bullet Boot pipe flashings and exhaust vent flashings |
| Type of structure |
House |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
1660 |
| No. of Stories |
1 |
| Roof Pitch |
4:12 or Greater |
| Is the existing roof being removed? |
Yes |
| Type of New Roofing Product |
Asphalt Shingles |
| Florida Product Approval Number |
FL10674.1 |
| Product Manufacturer |
Owens Corning |
| Product Description |
OC Duration TruDef Estate Gray |
| Building Code Edition |
2020 Florida Building Code 7th Edition and Florida Statute 553.844 |
| Sealed roof decking options: (Must select an option.) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
| Ventilation: |
Off-ridge Vent |
| Flashing: |
Use Existing |
| Drip Edge: |
Replace All |
| Valley Treatment: |
New Metal |
| Second Roof Pitch (if applicable) |
2:12 to 4:12 |
| Any cable and/or race-way wiring located on or within the roof assembly? |
No |