Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Mobile Home Permit
Address 385 SW SUMAC LN
LAKE CITY, FL 32024
Parcel #: 03231-011
Acres: 10.00
Owner: Williams Joan V
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 55524
Permit #: 000045182
Related Permit:
Submitted: Tuesday, July 5, 2022
Issued: Tuesday, August 16, 2022
Expires: Tuesday, February 14, 2023
Completed: Tuesday, February 14, 2023
Status: Completed
Septic Release? Yes
Notes:
FINISHED FLOOR ONE FOOT ABOVE ROAD OR ENGINEER LETTER WITH SURVEYOR CONFIRMATION ELEVATION CONFIRMATION REC'D @ 101.9'
Job Details
Mobile Home is a: Double Wide
Year Built 2022
Width (Ft.In) 28
Length (Ft.In) 56
Wind Zone? 2
Serial # 050-000-H-A000722AB
Installation Decal # 90724
Service Amps 200
Residential or Commercial Use? Residential
Driveway access to home: Existing Drive
Are you applying for a 5 year temporary permit? No
Septic # (00-0000) or (X00-000) 22-0609
Dev Permit # F023-
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Elevation regulation Engineers Elevation Letter
Finished floor requirement 99.50'
Requirement needed By Final Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0380C
In floodway N
Review Notes
7/5/2022 Application pending.
7/5/2022 Point Review - Printed-Online Application NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * MH INSTALLERS AUTHORIZATION * SUBCONTRACTOR FORM
7/5/2022 Point Review - Reviewed NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * MH INSTALLERS AUTHORIZATION * SUBCONTRACTOR FORM
7/11/2022 Zoning Review - Reviewed NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * MH INSTALLERS AUTHORIZATION * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
7/11/2022 Plan Review - Reviewed NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * MH INSTALLERS AUTHORIZATION * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
7/11/2022 Final Review - Documents Required NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * MH INSTALLERS AUTHORIZATION * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
7/12/2022 Final Review - Documents Required NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * MH INSTALLERS AUTHORIZATION * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
7/18/2022 Final Review - Documents Required NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * MH INSTALLERS AUTHORIZATION * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
7/19/2022 Final Review - Documents Required NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * MH INSTALLERS AUTHORIZATION * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/1/2022 Final Review - Documents Required NEEDED * SERIAL # * ENVIROMENTAL HEALTH RELEASE- CONTACT 386-758-1008 * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/3/2022 Final Review - Documents Required NEEDED * SERIAL # * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/4/2022 Final Review - Documents Required NEEDED * SERIAL # * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/8/2022 Final Review - Documents Required NEEDED * SERIAL # * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/9/2022 Final Review - Documents Required NEEDED * SERIAL # * SUBCONTRACTOR FORM **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/15/2022 Final Review - Documents Required NEEDED *SIGNED SUBCONTRACTOR FORM-- **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/15/2022 Final Review - Reviewed **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/15/2022 Final Review - Payment Needed **THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION AT THE ROAD AND THE ELEVATION AT THE PROPOSED HOME SITE. IF THE MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED
8/16/2022 Permit Issued Permit #000045182 created and approved.
Contractors
Name/ Business License Title Role
Ernest S Johnson
Dependable Mobile Home Service
County License & State License Expired.
IH1025249 Mh Installer (ih) Contractor
Glenn Whittington
Whittington Electric Inc
EC13002957 Electrical Contractor Subcontractor
Timothy D Shatto
Shatto Heating & Air, Inc.
CAC057875 A/c Class B Subcontractor
Inspections
Inspection Notes Performed By Date
Failed: Building - Footer Need Engineers Letter Required By Permit Matt Forsyth 11/8/2022
Cancelled: Engineering - Setbacks Matt Forsyth 11/8/2022
Septic Release Inspection Health Dept 11/14/2022
Cancelled: Building - Footer Emaleigh Williams 2/7/2023
Cancelled: Engineering - Setbacks Emaleigh Williams 2/7/2023
Passed: Engineering - Setbacks Per Letter Gary Pitzer 2/8/2023
Failed: Mobile Home - Mobile Home Set-Up Final Dryer Flex On Ground, Electric Bonding In Effect, Waste Piping On Top Of Ground One Poorly Supported Gary Pitzer 2/8/2023
Passed: Engineering - Setbacks Gary Pitzer 2/14/2023
Passed: Mobile Home - Mobile Home Set-Up Final Gary Pitzer 2/14/2023
Release to power company Gary Pitzer 2/14/2023