Permit Details

Permit Search

Permit

Solar Power System

208 SE TEVIS AVE
LAKE CITY, FL 32025

Permit #
000045180
Application #
55928
Status Completed
  1. Submitted Aug 3, 2022
  2. Issued Aug 16, 2022
  3. Expires Jun 25, 2023
  4. Completed Dec 27, 2022

Property

Parcel #
08346-051
Owner
Thornton Barbara Ann
Acres
2.11
Subdivision
Price Creek Unr
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0315C
PV Type
Utility Interactive PV System- (DC to AC with utility connection)
Grounding
N.E.C. Chapter 690
AC Options
Exposed;USE-2
AC Options (Cont..)
In Conduit;THWN-2
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Power Company
Florida Power and Light
Residential or Commercial?
Residential
Where are the panels mounted?
Roof Mounted
Service Amps
32

Status & Review History

  1. Application pending.
  2. City of Lake City Utilities Notified
  3. Point Review - Processing
  4. Plan Review - Reviewed
  5. Zoning Review - Reviewed
  6. Final Review - Reviewed
  7. Final Review - Reviewed
  8. Final Review - Payment Needed
  9. Permit Issued

Contractors

  • Michael C Pasternak

    Atlantic Key Energy

    License
    EC13009713
    Title
    Cert. Electrical
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Oct 24, 2022

    Passed: Electrical - Permanent Power

    Inspected by Anthony Aslan

  2. Oct 24, 2022

    Release to power company

    Inspected by Anthony Aslan

  3. Nov 17, 2022

    Failed: Solar - Solar Final

    Ground Doesn't Match Engineer Drawings, Bare Ground Installed Drawing Calls For 10ga. Thwn-2 Copper

    Inspected by Anthony Aslan

  4. Dec 27, 2022

    Passed: Solar - Solar Final

    Corrections Made

    Inspected by Anthony Aslan

  5. Dec 27, 2022

    Release to power company

    Inspected by Anthony Aslan