Permit Details

Permit Search

Permit

New Residential Construction

171 NW AMBLESIDE DR
LAKE CITY, FL 32055

Permit #
000045149
Application #
55683
Status Completed
  1. Submitted Jul 13, 2022
  2. Issued Sep 19, 2022
  3. Expires Mar 13, 2024
  4. Completed Sep 18, 2023

Property

Parcel #
02275-121
Owner
Flanders Michael, Flanders Maureen
Acres
2.12
Subdivision
Cobblestone Unit 1
Zoning
RR
Flood zone
X
District
1

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
162.10'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0283D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2298
Total Area (Sqft)
2934
Building Height
23
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0627
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Plan Review - Documents Required
  4. Plan Review - Corrections Needed
  5. Plan Review - Building Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Plumbing Approved
  9. Plan Review - Fuel/Gas Approved
  10. Plan Review - Reviewed
  11. Zoning Review - Reviewed
  12. Final Review - Reviewed
  13. Final Review - Reviewed
  14. Final Review - Payment Needed
  15. Permit Issued
  16. Permit Reissued

Contractors

  • Matthew A Erkinger,sr.

    Erkinger Construction Group

    License
    CRC1330825
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance Expired.

  • Marcus Matthews

    Matthews Electric Llc

    License
    EC13005459
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Richard C Register

    Register's Heating & Air Conditioning,inc.

    License
    CAC041267
    Title
    Class B
    Role
    Subcontractor

    County License & State License & Liability Insurance Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Wallace W Powell

    Powell & Sons Roofing,inc.

    License
    CCC057307
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Aug 25, 2022

    Passed: Building - Footer

    Need Porta Potty

    Inspected by Anthony Aslan

  2. Aug 25, 2022

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  3. Oct 21, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  4. Oct 21, 2022

    Passed: Electrical - Temporary Service

    Need Ground Connected In Meter Can.

    Inspected by Anthony Aslan

  5. Oct 28, 2022

    Passed: Building - Slab

    Inspected by Anthony Aslan

  6. Oct 28, 2022

    Passed: Electrical - Temporary Service

    Correction Made

    Inspected by Anthony Aslan

  7. Oct 28, 2022

    Release to power company

    Inspected by Anthony Aslan

  8. Jan 4, 2023

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  9. Jan 4, 2023

    Cancelled: Building - Strapping

    Inspected by Anthony Aslan

  10. Jan 4, 2023

    Failed: Building - Roof Decking

    Not Ready

    Inspected by Anthony Aslan

  11. Jan 4, 2023

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Inspected by Anthony Aslan

  12. Jan 12, 2023

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  13. Jan 26, 2023

    Passed: Building - Framing

    Inspected by Anthony Aslan

  14. Jan 26, 2023

    Passed: Electrical - 2nd Rough-In

    Nail Guards Missing In Some Spots

    Inspected by Anthony Aslan

  15. Jan 26, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  16. Jan 26, 2023

    Failed: Mechanical - Rough In

    Dryer Pipe Ovaled At Top Plate flex Not Sealed To Boots And Mixing Boxes exhaust Flex Not Strapped, Hall Bath Exhaust Flex Vented Over Window Not Allowed

    Inspected by Anthony Aslan

  17. Mar 9, 2023

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  18. Mar 9, 2023

    Passed: Building - Insulation

    Inspected by Anthony Aslan

  19. Aug 18, 2023

    Cancelled: Electrical - Permanent Power

    Inspected by Melissa Garber

  20. Aug 22, 2023

    Passed: Electrical - Permanent Power

    Need Septic Release

    Inspected by Anthony Aslan

  21. Aug 28, 2023

    Release to power company

    Inspected by Melissa Garber

  22. Aug 28, 2023

    Septic Release Inspection

    Inspected by Health Dept

  23. Sep 15, 2023

    Passed: Building - Final

    Outside Air Does Not Exist The Soffit. r303.5opening Location. outdoor Intake And Exhaust Openings Shall Be Located In Accordance With Sections R303.5.1 And R303.5.2. r303.5.1intake Openings. mechanical And Gravity Outdoor Air Intake Openings Shall Be Located Not Less Than 10 Feet (3048 Mm) From Any Hazardous Or Noxious Contaminant, Such As Vents, Chimneys, Plumbing Vents, Streets, Alleys, Parking Lots And Loading Docks. for The Purpose Of This Section, The Exhaust From Dwelling Unit Toilet Rooms, Bathrooms And Kitchens Shall Not Be Considered As Hazardous Or Noxious. exceptions: 1.the 10-foot (3048 Mm) Separation Is Not Required Where The Intake Opening Is Located 3 Feet (914 Mm) Or Greater Below The Contaminant Source. 2.vents And Chimneys Serving Fuel-burning Appliances Shall Be Terminated In Accordance With The Applicable Provisions Of Chapters 18 And 24. 3.clothes Dryer Exhaust Ducts Shall Be Terminated In Accordance With Section M1502.3. r303.5.2exhaust Openings. exhaust Air Shall Not Be Directed Onto Walkways. r303.6outside Opening Protection. air Exhaust And Intake Openings That Terminate Outdoors Shall Be Protected With Corrosion-resistant Screens, Louvers Or Grilles Having An Opening Size Of Not Less Than 1/4 Inch (6 Mm) And A Maximum Opening Size Of 1/2 Inch (13 Mm), In Any Dimension. Openings Shall Be Protected Against Local Weather Conditions. Outdoor Air Exhaust And Intake Openings Shall Meet The Provisions For Exterior Wall Opening Protectives In Accordance With This Code.

    Inspected by Anthony Aslan

  24. Sep 18, 2023

    Certificate-Release Certificate

    Rec'd Pictures

    Inspected by Anthony Aslan

Documents