Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 2557 SW OLD WIRE RD
LAKE CITY, FL 32024
Parcel #: 03707-109
Acres: 5.00
Owner: Zieger William Edward Jr, Zieger Sandra Jean
Subdivision: Paradise South
Zoning: A-3
Flood Zone: X
District: 5
Application #: 55419
Permit #: 000045064
Related Permit:
Submitted: Tuesday, June 28, 2022
Issued: Thursday, July 28, 2022
Expires: Friday, April 21, 2023
Completed: Friday, April 21, 2023
Status: Completed
Septic Release? Yes
Notes:
MINIMUM FLOOR ELEVATION - 1' ABOVE THE ROAD
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0395C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1584
Total Area (Sqft) 3024
Building Height 19
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0010
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
6/28/2022 Point Review - Received-Hard Copy Application NEEDED: *OWNERS PHONE NUMBER *CRAWFORD UPDATED LIABILITY *BILLS WORKERS COMP *POWER COMPANY SELECTED *ROOF OPTION SELECTED *ENV HEALTH APPROVAL-- CONTACT 386-758-1058
6/28/2022 Point Review - Reviewed NEEDED: *OWNERS PHONE NUMBER *CRAWFORD UPDATED LIABILITY *BILLS WORKERS COMP *POWER COMPANY SELECTED *ROOF OPTION SELECTED *ENV HEALTH APPROVAL-- CONTACT 386-758-1058
7/8/2022 Plan Review - Corrections Needed NEEDED: *OWNERS PHONE NUMBER *CRAWFORD UPDATED LIABILITY *BILLS WORKERS COMP *POWER COMPANY SELECTED *ROOF OPTION SELECTED *TAMKO PRODUCT APPROVAL NOT IN CURRENT CODE 2020 *ENV HEALTH APPROVAL-- CONTACT 386-758-1058
7/11/2022 Plan Review - Corrections Needed NEEDED: *OWNERS PHONE NUMBER *CRAWFORD UPDATED LIABILITY *BILLS WORKERS COMP *POWER COMPANY SELECTED *ROOF OPTION SELECTED *PLANS SHOW DOUBLE BOTTOM PLATE IN GARAGE?
7/12/2022 Plan Review - Contact the Building Dept NEEDED: *OWNERS PHONE NUMBER *BILLS WORKERS COMP *ROOF OPTION SELECTED *PLANS SHOW DOUBLE BOTTOM PLATE IN GARAGE?
7/19/2022 Plan Review - Contact the Building Dept NEEDED: *OWNERS PHONE NUMBER *BILLS WORKERS COMP *ROOF OPTION SELECTED *PLANS SHOW DOUBLE BOTTOM PLATE IN GARAGE?
7/19/2022 Plan Review - Building Approved
7/19/2022 Plan Review - Electrical Approved
7/19/2022 Plan Review - Mechanical Approved
7/19/2022 Plan Review - Plumbing Approved
7/19/2022 Point Review - Reviewed
7/20/2022 Zoning Review - Reviewed
7/21/2022 Plan Review - Reviewed
7/21/2022 Final Review - Reviewed
7/26/2022 Final Review - Reviewed
7/26/2022 Final Review - Payment Needed
7/28/2022 Permit Issued Permit #000045064 created and approved.
3/3/2023 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
William S Crawford
Stanley Crawford Construction Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
RG0042896 General Contractor Contractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Stephen M Brisbois
Epic Ac Service (dba) Central Home Heating & Air Llc
Workers Comp Expired.
CAC1819412 Cert. A/c Class “b” Subcontractor
Ralph W Laverdure
Rwl Roofing Llc
CCC1328590 Roofing Contractor Subcontractor
Don C Bills Jr
Hometown Plumbing Services Llc
County License Expired.
Plumbing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 7/11/2022
Passed: Building - Footer Compaction Test Was Done Troy Crews 8/8/2022
Passed: Engineering - Setbacks Troy Crews 8/8/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 8/18/2022
Passed: Building - Slab Troy Crews 8/25/2022
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 9/13/2022
Passed: Building - Roof Decking Troy Crews 9/13/2022
Passed: Building - Framing Troy Crews 10/5/2022
Passed: Building - Strapping Troy Crews 10/5/2022
Passed: Electrical - 2nd Rough-In Troy Crews 10/5/2022
Passed: Mechanical - Rough In Troy Crews 10/5/2022
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 10/5/2022
Passed: Building - Insulation Troy Crews 10/20/2022
Cancelled: Electrical - Temporary Service Troy Crews 3/3/2023
Cancelled: Electrical - Permanent Power Troy Crews 3/3/2023
Passed: Electrical - Permanent Power Troy Crews 3/3/2023
Release to power company Troy Crews 3/3/2023
Passed: Building - Final Troy Crews 4/20/2023
Documents
File Name Date File Size
Lidar 55419 2022-07-20 15.33.49.761.pdf 2025.07.05 77.58kB
911 Address Form 20220801 104146.pdf 2025.07.05 148.42kB
Subcontractor Form 20220801 104147.pdf 2025.07.05 192.09kB
Product Approval Code Specifications Form 20220801 104247.pdf 2025.07.05 199.25kB
Site Plan 20221021 011846.pdf 2025.07.05 164.35kB
Subcontractor Form 20220801 100100.pdf 2025.07.05 195.55kB
Application Information Page 20220801 095846.pdf 2025.07.05 228.17kB
Product Approval Code Specifications Form 20220801 091251.pdf 2025.07.05 231.29kB
Owner And Contractor Signature Page 20220801 104049.pdf 2025.07.05 372.57kB
Zieger Eh 2022-07-11 08.25.46.803.pdf 2025.07.05 660.00kB
Residential Or Commercial Checklist 20220801 104246.pdf 2025.07.04 1.06MB
Manual J Forms 20220801 091148.pdf 2025.07.04 914.47kB
Energy Code Forms 20220801 104746.pdf 2025.07.04 1.03MB
Noc & Deed.pdf 2025.07.04 731.16kB
45064 Plans.pdf 2025.07.04 1.26MB
Truss Engineering 20221021 011848.pdf 2025.06.26 9.45MB
Certificate Of Occupancy 20230421.pdf 2025.06.23 69.01kB
Original Permit 20220728.pdf 2025.06.22 51.85kB
Win_20220825_15_52_29_pro 2022-08-25 15.55.38.363.jpg 2025.06.20 169.68kB
45064 Blower Door 2023-04-21 07.14.17.348.jpg 2025.06.20 3.07MB
Garage Detail G Correction 55419 2022-07-19 13.01.59.05.pdf 2023.12.23 217.51kB
Zieger _ Detail G Correction 2022-07-19 12.45.41.361.pdf 2023.12.23 183.14kB
Septic Permitt 55419 2022-07-12 13.53.34.425.pdf 2023.12.23 926.42kB
Power Release-electrical-permanent Power 20230303.pdf 2023.03.03 38.85kB