Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 343 SW FEDERAL CT
FORT WHITE, FL 32038
Parcel #: 03745-319
Acres: 5.13
Owner: Seely Pamela M,
Subdivision: Sunview Estates Addition
Zoning: ESA-2
Flood Zone: X
District: 2
Application #: 55094
Permit #: 000044912
Related Permit:
Submitted: Thursday, June 2, 2022
Issued: Friday, July 8, 2022
Expires: Tuesday, February 14, 2023
Completed: Tuesday, February 14, 2023
Status: Completed
Septic Release? Yes
Notes:
SURVEYOR CONFIRMATION OF FINISHED FLOOR REQUIRED AT 63.50 OR GREATER ELEVATION CONFIRMATION REC'D @ 63.75'
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 63.50'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved No
Fema map number 12023C0390C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 2
Heated Area (Sqft) 960
Total Area (Sqft) 1440
Building Height 15
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0372
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
6/2/2022 Point Review - Received-Hard Copy Application NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION
6/2/2022 Point Review - Reviewed NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION
6/8/2022 Plan Review - Corrections Needed NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION *EGRESS WINDOW IN UP STAIRS BEDROOM DON'T MEET CODE
6/14/2022 Plan Review - Building Approved NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION
6/14/2022 Plan Review - Electrical Approved NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION
6/14/2022 Plan Review - Mechanical Approved NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION
6/14/2022 Plan Review - Plumbing Approved NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION
6/14/2022 Plan Review - Reviewed NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION
6/17/2022 Zoning Review - Documents Required NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION OWNER TO PROVIDE ENGINEER LETTER FOR FLOOR ELEVATION 6-16-22 TC
6/24/2022 Zoning Review - Documents Required NEEDED: *ENV HEALTH-- CONTACT 386-758-1058 *EST COST OF CONSTRUCTION OWNER TO PROVIDE ENGINEER LETTER FOR FLOOR ELEVATION 6-16-22 TC OR HAVE CONTRACTOR CHECK ONE FOOT ABOVE ROAD WITH TRANSIT
6/27/2022 Zoning Review - Reviewed
6/27/2022 Final Review - Reviewed
7/8/2022 Permit Issued Permit #000044912 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 6/9/2022
Passed: Building - Footer Matt Forsyth 8/8/2022
Passed: Engineering - Setbacks Matt Forsyth 8/8/2022
Passed: Building - Slab Floor Framing Inspected Matt Forsyth 11/4/2022
Failed: Building - Masonry Wall Reinforcing Need Elevation Confirmation From Surveyor Prior To Further Inspections Troy Crews 11/17/2022
Passed: Building - Ext Strapping/Wall Sheathing Inspection Was For Roof Sheathing Also Matt Forsyth 12/2/2022
Documents
File Name Date File Size
Original Permit 20220708.pdf 2025.07.05 28.60kB
Permit M55094 And 55099 2023-02-14 09.46.21.872.pdf 2025.07.05 48.97kB
Application Information Page 20220725 030646.pdf 2025.07.05 239.16kB
Recorded Notice Of Commencement 20220725 031047.pdf 2025.07.05 241.93kB
Recorded Deed 20220725 031046.pdf 2025.07.05 303.83kB
Owner And Contractor Signature Page 20220725 030748.pdf 2025.07.05 367.78kB
Subcontractor Form 20220725 030946.pdf 2025.07.05 408.35kB
Property Appraiser Parcel Details Printed Page 20220725 030947.pdf 2025.07.05 478.16kB
Approved Updated Plans 55094 2022-06-14 13.58.23.01.pdf 2025.07.04 714.54kB
Owner Disclosure Statement 20220725 030948.pdf 2025.07.04 788.57kB
Updated Plans.pdf 2025.06.26 3.37MB
Site Plan 20220725 030747.pdf 2025.06.22 123.99kB
Surveyor Letter Giving The Finished Floor Elevation 20230112 101846.pdf 2025.06.22 129.06kB
Roof Inspection Affidavit By Contractor 20220725 030949.pdf 2025.06.22 193.82kB
Product Approval Code Specifications Form 20220725 031047.pdf 2025.06.22 230.55kB
911 Address.pdf 2025.06.21 161.84kB
Manual J Forms 20220725 031247.pdf 2025.06.21 872.47kB
Energy Code Forms 20220725 031248.pdf 2025.06.21 1.17MB
Residential Or Commercial Checklist 20220725 031246.pdf 2025.06.21 1.66MB
Elevation Letter 343 Sw Federal Court Fort White Fl 06-22-22.pdf 2025.06.21 730.84kB
44912 Plans.pdf 2025.06.21 638.19kB
Pamela Seely - Final Plans 2022-08-23 08.10.45.759.pdf 2025.06.20 3.70MB
Sunview_estates_add 2022-06-02 17.12.44.137.pdf 2025.06.19 13.01MB
Seely Eh.pdf 2022.06.09 1,023.29kB