Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 267 SW TIMBERLAND CT
LAKE CITY, FL 32024
Parcel #: 02438-176
Acres: 0.50
Owner: Amaya Kellum
Subdivision: Emerald Cove Phase 2
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 54597
Permit #: 000044868
Related Permit: Culvert: 000044869
Submitted: Friday, May 20, 2022
Issued: Tuesday, July 5, 2022
Expires: Friday, January 27, 2023
Completed: Friday, January 27, 2023
Status: Completed
Septic Release? Yes
Notes:
ELEVATION CONIRMATION REC'D @ 112.89'
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 112'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 1603
Total Area (Sqft) 2330
Building Height 18
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0545
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
4/29/2022 Application pending.
5/20/2022 Point Review - Processing
5/24/2022 Point Review - Printed-Online Application
5/24/2022 Point Review - Reviewed
5/25/2022 Plan Review - Building Approved
5/25/2022 Plan Review - Electrical Approved
5/25/2022 Plan Review - Mechanical Approved
5/25/2022 Plan Review - Plumbing Approved
5/25/2022 Plan Review - Reviewed
5/26/2022 Zoning Review - Reviewed
5/31/2022 Final Review - Reviewed
6/1/2022 Final Review - Documents Required
7/1/2022 Final Review - Reviewed
7/1/2022 Final Review - Payment Needed
7/5/2022 Permit Issued
9/13/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Bryan Zecher
Bryan Zecher Homes Inc
CBC1257343 Building Contractor Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Robert Ogles
Ogles Roofing & Construction Llc
CCC1328699 Cert Roofing Subcontractor
Donald R Hollingsworth
Holly Electric Inc
EC13005429 Electrical Subcontractor
Anthony R Franks
Lane Heating & Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Matt Forsyth 7/12/2022
Passed: Engineering - Setbacks Matt Forsyth 7/12/2022
Passed: Electrical - Temporary Service Matt Forsyth 7/25/2022
Release to power company Matt Forsyth 7/25/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 7/27/2022
Passed: Building - Slab Troy Crews 8/4/2022
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 9/8/2022
Passed: Building - Framing Clean Job Site And Nice Framing Matt Forsyth 9/13/2022
Cancelled: Electrical - Permanent Power Matt Forsyth 9/15/2022
Passed: Engineering - Initial Driveway Smith, Blake 9/22/2022
Passed: Electrical - 2nd Rough-In Matt Forsyth 9/23/2022
Passed: Mechanical - Rough In Matt Forsyth 9/23/2022
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 9/23/2022
Passed: Plumbing/Gas - Tub Set/Shower Pan Tub Needs Water For Testing Matt Forsyth 9/23/2022
Passed: Building - Insulation Walls Matt Forsyth 10/4/2022
Passed: Electrical - Permanent Power Septic And Drive Releases Needed Matt Forsyth 12/2/2022
Release to power company Matt Forsyth 12/2/2022
Cancelled: Engineering - Final Driveway Emaleigh Williams 12/22/2022
Passed: Engineering - Final Driveway Needs To Remove Dirt From Ditch Smith, Blake 1/10/2023
Septic Release Inspection Health Dept 1/11/2023
Passed: Building - Final Matt Forsyth 1/27/2023
Documents