Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 830 W DUVAL ST
LAKE CITY, FL 32055
Parcel #: 12502-000
Acres:
Owner: Blow Ryderwood Llc
Subdivision: Mcfarlane Park
Zoning:
Flood Zone: X
District: 5
Application #: 55195
Permit #: 000044810
Related Permit:
Submitted: Friday, June 24, 2022
Issued: Monday, June 27, 2022
Expires: Tuesday, July 12, 2022
Completed: Tuesday, July 12, 2022
Status: Completed
Septic Release? na
Notes:
LAKE CITY UTLITY CUSTOMER SERVICE NOTES THE COLC HAS ACTIVE WATER AND SEWER AT THIS LOCATION. THERE ARE GAS LINES IN THE AREA. LAKE CITY CODE ENFORCEMENT CASE NOTES NONE PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) replace bad decking as needed
Type of structure Commercial Building
Commercial or Residential Commercial
Roof Area (for this job) Sq Ft 2600
No. of Stories 1
Ventilation: Off-ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Second Roof Pitch (if applicable) 2:12 to 4:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL101-24
Product Manufacturer GAF
Product Description Asphalt Shingle
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0284D
Review Notes
6/14/2022 Application pending.
6/24/2022 City of Lake City City of Lake City Notified of Application within City of Lake City LC_GAS, LC_WATER, LC_SEWER.
6/24/2022 Final Review - Documents Required NEEDED: *OWNERS PHONE NUMBER *CITY APPROVAL LETTER-- PENDING ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/27/2022 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/27/2022 Permit Issued Permit #000044810 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Troy Crews 7/1/2022
Passed: Re-Roof - Final Troy Crews 7/12/2022